A | B | C | D | E | F | G | H | I | J | K | L | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Table C-2: NOx Reductions from the Application of NOx RACT (Reductions by Categories) | ||||||||||||
2 | |||||||||||||
3 | |||||||||||||
4 | Emission Category Description | Category Designation | No. of Entries | No. of Units | Heat Input mmbtu/hr | 2005 NOx Emissions tpy | Estimated NOx RACT Reduction , % | Estimated Controlled NOx tpy | Estimated Nox Reduction Tons | Unit Typical Ozone Season NOx tons/day | Estimated Ozone Season Controlled NOx, TPD | Estimated Ozone season NOx Reduction, TPD | |
5 | Chicago NAA | ||||||||||||
6 | Gaseous Fuel-fired Boilers >100 mmBtu/hr, Total | 1a1 | 22 | 34 | 6911.9 | 1196.5 | 69.2% | 368.2 | 828.3 | 2.79 | 0.86 | 1.93 | |
7 | Gaseous fuel-fired Boilers < =100 mmBtu/hr, Total | 1a2 | 6 | 20 | 1273.9 | 156.6 | 15.0% | 133.1 | 23.5 | 0.63 | 0.54 | 0.09 | |
8 | Dist. oil Boilers >100 mmBtu/hr, Total | 1b1 | 1 | 1 | 249 | 22.3 | 52.4% | 10.6 | 11.7 | 0.040 | 0.02 | 0.02 | |
9 | Solid Fuel Boilers >250 mmbtu/hr, Total | 1e2 | 3 | 3 | 997.5 | 2330.2 | 73.9% | 607.9 | 1722.3 | 8.93 | 2.33 | 6.60 | |
10 | Solid Fuel <=250, >100 mmbtu/hr, Total | 1e3 | 1 | 1 | 212 | 21.6 | 63.8% | 7.8 | 13.8 | 0.00 | 0.00 | 0.00 | |
11 | Solid Fuel Boilers <=100 mmbtu/hr, Total | 1e4 | 5 | 5 | 376.2 | 476.7 | 15.0% | 405.2 | 71.5 | 1.61 | 1.37 | 0.24 | |
12 | Process Htrs Gas fired >100 mmBtu/hr, Total | 2a1 | 16 | 41 | 6672.6 | 1526.0 | 28.6% | 1090.0 | 436.0 | 4.19 | 2.99 | 1.20 | |
13 | Process Htrs Gas-fired< =100 mmBtu/hr, Total | 2a2 | 9 | 10 | 720.3 | 213.3 | 15.0% | 181.3 | 32.0 | 0.60 | 0.51 | 0.09 | |
14 | Process Htrs, Residual Oil-fired, >100 mmBtu/hr, Total | 2b1 | 1 | 1 | 171 | 23.3 | 76.2% | 5.5 | 17.7 | 0.07 | 0.02 | 0.05 | |
15 | Process Htrs, Other Oil-fired, <100 mmBtu/hr, Total | 2c3 | 1 | 1 | 17 | 26.5 | 15.0% | 22.5 | 4.0 | 0.10 | 0.09 | 0.02 | |
16 | Glass melting Furnaces, Total | 3 | 1 | 4 | 45 | 731.9 | 50.0% | 366.0 | 366.0 | 2.02 | 1.01 | 1.01 | |
17 | Lime Kilns, Total | 5a | 2 | 2 | 588.9 | 734.4 | 30.0% | 514.1 | 220.3 | 2.54 | 1.78 | 0.76 | |
18 | Annealing Furnace, Iron and Steel, Total | 7b | 1 | 1 | 123 | 44.1 | 60.0% | 17.6 | 26.5 | 0.15 | 0.06 | 0.09 | |
19 | EGU Coal-fired Boilers, Total | 8a | 13 | 15 | 37802 | 24827.2 | 57.3% | 10612.9 | 14214.3 | 82.22 | 34.59 | 47.63 | |
20 | All Sources in Chicago NAA, Total | 82 | 139 | 56160.30 | 32331 | 56% | 14343 | 17988 | 105.9 | 46.2 | 59.7 | ||
21 | Metro-East NAA | ||||||||||||
22 | Gaseous Fuel-fired Boilers >100 mmBtu/hr, Total | 1a1 | 10 | 6 | 3460 | 730.1 | 69.2% | 224.6 | 505.4 | 2.02 | 0.62 | 1.40 | |
23 | Gaseous Fuel-fired Boilers <=100 mmBtu/hr, Total | 1a2 | 7 | 10 | 1305 | 364.9 | 15.0% | 310.2 | 54.7 | 1.06 | 0.90 | 0.16 | |
24 | Process Htrs Gas fired >100 mmBtu/hr, Total | 2a1 | 16 | 16 | 2776.7 | 2184.4 | 28.6% | 1560.3 | 624.1 | 6.58 | 4.70 | 1.88 | |
25 | Process Htrs Gas fired <100 mmBtu/hr, Total | 2a2 | 15 | 15 | 1395.3 | 765.2 | 15.0% | 650.4 | 114.8 | 2.10 | 1.78 | 0.31 | |
26 | Reheat Furnaces, Iron and Steel, Total | 7a | 8 | 5 | 2681.6 | 1008.5 | 77.0% | 231.9 | 776.5 | 4.62 | 1.06 | 3.56 | |
27 | EGU Coal-fired Boilers, Total | 8a | 5 | 5 | 22540 | 7241 | 8.3% | 6639 | 602 | 20.6 | 18.8 | 1.8 | |
28 | All Sources in Metro-East NAA, Total | 61 | 57 | 34158.60 | 12294 | 21.8% | 9617 | 2678 | 37.0 | 27.9 | 9.1 | ||
29 | Chicago and Metro-East NAA (Combined) | ||||||||||||
30 | Gaseous Fuel-fired Boilers >100 mmBtu/hr, Total | 1a1 | 32 | 40 | 10371.9 | 1926.5 | 69% | 592.8 | 1333.8 | 4.8 | 1.5 | 3.3 | |
31 | Gaseous fuel-fired Boilers < =100 mmBtu/hr, Total | 1a2 | 13 | 30 | 2578.9 | 521.5 | 15% | 443.3 | 78.2 | 1.7 | 1.4 | 0.3 | |
32 | Dist. oil Boilers >100 mmBtu/hr, Total | 1b1 | 1 | 1 | 249 | 22.3 | 52.4% | 10.6 | 11.7 | 0.040 | 0.02 | 0.02 | |
33 | Solid Fuel Boilers >250 mmbtu/hr, Total | 1e2 | 3 | 3 | 997.5 | 2330.2 | 73.9% | 607.9 | 1722.3 | 8.93 | 2.33 | 6.60 | |
34 | Solid Fuel <=250, >100 mmbtu/hr, Total | 1e3 | 1 | 1 | 212 | 21.6 | 63.8% | 7.8 | 13.8 | 0.00 | 0.00 | 0.00 | |
35 | Solid Fuel Boilers <=100 mmbtu/hr, Total | 1e4 | 5 | 5 | 376.2 | 476.7 | 15.0% | 405.2 | 71.5 | 1.61 | 1.37 | 0.24 | |
36 | Process Htrs Gas fired >100 mmBtu/hr, Total | 2a1 | 32 | 57 | 9449.3 | 3710.4 | 0.6 | 2650.3 | 1060.1 | 10.8 | 7.7 | 3.1 | |
37 | Process Htrs Gas-fired< =100 mmBtu/hr, Total | 2a2 | 24 | 25 | 2115.6 | 978.5 | 0.3 | 831.7 | 146.8 | 2.7 | 2.3 | 0.4 | |
38 | Process Htrs, Residual Oil-fired, >100 mmBtu/hr, Total | 2b1 | 1 | 1 | 171 | 23.3 | 76.2% | 5.5 | 17.7 | 0.07 | 0.02 | 0.05 | |
39 | Process Htrs, Other Oil-fired, <100 mmBtu/hr, Total | 2c3 | 1 | 1 | 17 | 26.5 | 15.0% | 22.5 | 4.0 | 0.10 | 0.09 | 0.02 | |
40 | Glass melting Furnaces, Total | 3 | 1 | 4 | 45 | 731.9 | 50.0% | 366.0 | 366.0 | 2.02 | 1.01 | 1.01 | |
41 | Lime Kilns, Total | 5a | 2 | 2 | 588.9 | 734.4 | 30.0% | 514.1 | 220.3 | 2.54 | 1.78 | 0.76 | |
42 | Reheat Furnaces, Iron and Steel, Total | 7a | 8 | 5 | 2681.6 | 1008.5 | 77.0% | 231.9 | 776.5 | 4.62 | 1.06 | 3.56 | |
43 | Annealing Furnace, Iron and Steel, Total | 7b | 1 | 1 | 123 | 44.1 | 60.0% | 17.6 | 26.5 | 0.15 | 0.06 | 0.09 | |
44 | EGU Coal-fired Boilers, Total | 8a | 18 | 20 | 60342.00 | 32068.6 | 46.2% | 17252.1 | 14816.5 | 102.9 | 53.4 | 49.4 | |
45 | All Sources in Chicago and Metro-East NAA, Total | 143 | 196 | 90318.9 | 44625 | 46.31% | 23959 | 20666 | 142.9 | 74.1 | 68.9 |
A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Table D-1: Year 2005 NOx Inventory of Major Sources in NAAs | ||||||||||||||||||
2 | Mydocument/TSD/NOx RACT-Attachments.xls | ||||||||||||||||||
3 | |||||||||||||||||||
4 | Sr. No. | Facility ID | Source PTE TPY NOx | Facility Name | SIC | Emission Unit ID | Emission Point Description | Mode ID | Mode Description | SCC # | Emission Unit category | Heat Input Capacity mmbtu/hr | 2005 NOx Emissions tpy | Unit Typical Ozone Season NOx tons/day | Fuel | descr1 | descr3 | descr4 | |
5 | 1 | 031003ADA | 516.7 | Alsip Paper Condominium Assn | 4931 | 0004 | BOILERS #1 AND #2 | 01 | 10200601 | 1a1 | 310 | 173.1 | 0.2184 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | ||
6 | 2 | 031012AAO | 139.6 | Nalco Co | 2899 | 0049 | BOILER #1 | 01 | NATURAL GAS COMBUSTION | 10200601 | 1a1 | 114.6 | 17.9 | 0.0656 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
7 | 3 | 031012AAO | 139.6 | Nalco Co | 2899 | 0061 | BOILER #2 | 01 | NATURAL GAS COMBUSTION | 10200601 | 1a1 | 124 | 42.3 | 0.2875 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
8 | 4 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0046 | UTILITIES - BOILER #5 (A-23-93) | 01 | 10200601 | 1a1 | 312.5 | 39.2 | 0.064 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | ||
9 | 5 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0160 | UTILITIES - BOILER #6 (A23-144) | 01 | 10200601 | 1a1 | 600 | 16.8 | 0.0384 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | ||
10 | 6 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0233 | UTILITIES - BOILER #7 | 01 | 10200601 | 1a1 | 240 | 30.5 | 0.087 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | ||
11 | 7 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0041 | UTILITIES - BOILER #1 (A-23-92) | 01 | 10200202 | 1e2 | 332.5 | 760.7 | 3.1979 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | ||
12 | 8 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0042 | UTILITIES - BOILER #2 (A-23-92) | 01 | 10200202 | 1e2 | 332.5 | 796.9 | 3.2401 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | ||
13 | 9 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0045 | UTILITIES - BOILER #3 (A-23-93) | 01 | 10200202 | 1e2 | 332.5 | 772.6 | 2.4953 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | ||
14 | 10 | 031045AAJ | 316.1 | Kimble Glass Inc | 0006 | GLASS MELTING FURNACE B | 01 | 30501402 | 3 | 25 | 50.8 | 0.14 | |||||||
15 | 11 | 031069AAI | 1113.0 | Saint-Gobain Containers Inc | 0013 | 3 GLASS MELTING FURNACES (1, 2 AND 3) | 01 | 30501402 | 3 | 120 | 681.2 | 1.87584 | NATURAL GAS | ||||||
16 | 12 | 031081AEQ | 286.5 | Northwestern University | 8221 | 0001 | 3 EC Boilers (#1, 2 and 3 - Central Utility Plant) | 01 | 10300601 | 1a1 | 556 | 156.7 | 0.4436 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MMBTU/HR | ||
17 | 13 | 031258ABR | 516.7 | Mittal Steel USA - Riverdale Inc | 3312 | 0184 | TUNNEL FURNACE | 01 | 30390003 | 7b | 123 | 44.1 | 0.1502 | NATURAL GAS | PRIMARY METAL PRODUCTION | PROCESS HEATERS | NATURAL GAS | ||
18 | 14 | 031600ADY | 1338.7 | Carmeuse Lime Inc | 3274 | 0024 | ROTARY KILN 4 | 01 | 30501605 | 5a | 155.6 | 250.4 | 0.9868 | PROPANE | MINERAL PRODUCTS | LIME MANUFACTURE | CALCIMATIC KILN | ||
19 | 15 | 031600ADY | 1338.7 | Carmeuse Lime Inc | 3274 | 0028 | ROTARY KILN 5 | 01 | 30501604 | 5a | 433.3 | 484.1 | 1.554 | PROPANE | MINERAL PRODUCTS | LIME MANUFACTURE | CALCINING: ROTARY KILN | ||
20 | 16 | 031600AIN | 32962.1 | Crawford Electric Generating Station | 4911 | 0013 | Unit 7 | 01 | Coal | 10100226 | 8a | 2342 | 873.9 | 2.746 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
21 | 17 | 031600AIN | 32962.1 | Crawford Electric Generating Station | 4911 | 0016 | Unit 8 | 01 | Coal | 10100226 | 8a | 3556 | 1375.0 | 4.1789 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
22 | 18 | 031600AMI | 13414.4 | Fisk Electric Generating Station | 4911 | 0010 | FISK UNIT #19 | 01 | COAL FIRING | 10100226 | 8a | 2896 | 1125.6 | 3.8275 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
23 | 19 | 031600CAO | 221.5 | Kraft Foods Global Inc | 2052 | 0107 | BOILER #5 | 01 | NATURAL GAS | 10200602 | 1a2 | 63.3 | 20.7 | 0.012 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
24 | 20 | 031600DDJ | 175.6 | National Railroad Passenger Corp | 4013 | 0001 | BOILER #1 | 01 | NATURAL GAS FIRING | 10200602 | 1a2 | 77.4 | 16.0 | 0 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
25 | 21 | 031600FLT | 204.3 | University of Chicago | 8221 | 0001 | BOILERS 1-4 | 01 | NATURAL GAS FIRING | 10200601 | 1a1 | 782 | 63.5 | 0.1142 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
26 | 22 | 031600FMX | 114.3 | Northwestern Memorial Hospital | 8062 | 0002 | 5 Boilers | 01 | Natural gas combustion | 10300602 | 1a2 | 126 | 31.8 | 0.0874 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
27 | 23 | 031600FQP | 202.5 | Chicago - Dept of Aviation | 4581 | 0003 | 8 HIGH TEMPERATURE WATER GENERATORS (HTWG-4001 - 4 | 01 | NATURAL GAS COMBUSTION | 10200602 | 1a2 | 758.6 | 26.0 | 0.3708 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
28 | 24 | 031817AAB | 108.9 | Loyola University Medical Center | 8221 | 0017 | BOILERS 2, 3 AND 4 | 01 | 10300602 | 1a2 | 154.9 | 20.6 | 0.0481 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | ||
29 | 25 | 031817AAL | 292.7 | VA Edward Hines Jr Hospital | 8062 | 0004 | BOILERS 1-4 | 01 | NATURAL GAS | 10300602 | 1a1 | 200 | 17.8 | 0.0231 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
30 | 26 | 043802AAA | 727.9 | Argonne National Laboratory | 8733 | 0001 | Boiler #1 | 01 | Natural Gas Combustion | 10300601 | 1a1 | 106 | 25.2 | 0.082 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MMBTU/HR | |
31 | 27 | 043802AAA | 727.9 | Argonne National Laboratory | 8733 | 0003 | Boiler #3 | 01 | Natural Gas Combustion | 10300601 | 1a1 | 106 | 19.4 | 0 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MMBTU/HR | |
32 | 28 | 043802AAA | 727.9 | Argonne National Laboratory | 8733 | 0004 | Boiler #4 | 01 | Natural Gas Combustion | 10300601 | 1a1 | 106 | 19.0 | 0 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MMBTU/HR | |
33 | 29 | 043802AAA | 727.9 | Argonne National Laboratory | 8733 | 0005 | Boiler #5 | 04 | Coal Firing | 10300205 | 1e3 | 212 | 21.6 | 0 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: WET BOTTOM | |
34 | 30 | 063800AAC | 628.1 | Equistar Chemicals LP | 2869 | 0025 | ETHYLENE PLANT - STEAM SUPERHEATER | 01 | 10200799 | 1a1 | 141 | 47.2 | 0.1294 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | > 100 MBTU/HR | ||
35 | 31 | 063800AAC | 628.1 | Equistar Chemicals LP | 2869 | 0026 | ETHYLENE PLANT - 14 CRACKING FURNACES (101-114) | 01 | 30600104 | 2a1 | 1277 | 357.3 | 0.9788 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | ||
36 | 32 | 063800AAE | 491.0 | Akzo Nobel Surface Chemistry LLC | 2869 | 0033 | STEAM BOILER J-090 (NEBRASKA) | 03 | PITCH FUEL FIRED | 10201201 | 1e4 | 40.2 | 37.1 | 0.2271 | OTHER | EXTERNAL COMBUSTION BOILERS | SOLID WASTE | SPECIFY WASTE MATERIAL IN COMMENTS | |
37 | 33 | 063800AAE | 491.0 | Akzo Nobel Surface Chemistry LLC | 2869 | 0017 | DOWTHERM BOILER | 02 | PITCH FUEL FIRED | 10201201 | 2c3 | 17 | 26.5 | 0.103 | OTHER | EXTERNAL COMBUSTION BOILERS | SOLID WASTE | SPECIFY WASTE MATERIAL IN COMMENTS | |
38 | 34 | 063800AAM | 243.8 | Aux Sable Liquid Products | 1321 | 0019 | Heaters 1H101, 2H101, H301, H601, H602, 501A, 501B | 01 | 39000699 | 2a1 | 859.3 | 156.1 | 0.4359 | NATURAL GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | ||
39 | 35 | 089800AAH | 711.8 | Dial Corp | 2841 | 0075 | BOILERS #1 AND #2 | 01 | NATURAL GAS | 10200601 | 1a1 | 210 | 124.1 | 0.3475 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
40 | 36 | 097125AAA | 582.3 | Abbott Laboratories | 2834 | 0858 | BOILER #10 NC (CED) | 01 | NATURAL GAS | 10200601 | 1a1 | 220 | 24.7 | 0.0761 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
41 | 37 | 097125AAA | 582.3 | Abbott Laboratories | 2834 | 0070 | BOILER #5NC (TT-16) (CED) | 01 | COAL FIRED | 10100204 | 1e4 | 85 | 85.5 | 0.2898 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | SPREADER STOKER | |
42 | 38 | 097125AAA | 582.3 | Abbott Laboratories | 2834 | 0242 | BOILER #6 NC (TT-20) (CED) | 01 | COAL FIRED | 10100204 | 1e4 | 85 | 77.1 | 0.2743 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | SPREADER STOKER | |
43 | 39 | 097190AAC | 47103.0 | Waukegan Electric Generating Station | 4911 | 0031 | UNIT #6 BOILER | 01 | COAL FIRING | 10100203 | 8a | 1024 | 1627.3 | 5.9705 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | CYCLONE FURNACE | |
44 | 40 | 097190AAC | 47103.0 | Waukegan Electric Generating Station | 4911 | 0033 | UNIT #8 BOILER | 01 | COAL FIRING | 10100226 | 8a | 3271 | 1595.4 | 4.6723 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
45 | 41 | 097190AAC | 47103.0 | Waukegan Electric Generating Station | 4911 | 0036 | UNIT #7 BOILER | 01 | COAL FIRING | 10100226 | 8a | 2911 | 1397.9 | 4.2667 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
46 | 42 | 097809AAD | 1629.2 | Abbott Laboratories | 2834 | 0006 | Boiler 4AP | 01 | Coal fired | 10200204 | 1e4 | 83 | 147.8 | 0.4492 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | SPREADER STOKER | |
47 | 43 | 097809AAD | 1629.2 | Abbott Laboratories | 2834 | 0103 | Boiler #5AP | 01 | Coal fired | 10200204 | 1e4 | 83 | 129.2 | 0.3739 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | SPREADER STOKER | |
48 | 44 | 097811AAC | 826.8 | Naval Training Center | 9711 | 0011 | BUILDING 11: BOILERS #5 AND #6 | 01 | NATURAL GAS COMBUSTION | 10200601 | 1a1 | 680 | 94.0 | 0.0341 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
49 | 45 | 119010AAE | 1916.7 | Alton Steel Inc | 3312 | 0033 | 14 INCH BILLET REHEAT FURNACE | 01 | GAS FIRED | 30300933 | 7a | 255 | 47.6 | 0.3174 | NATURAL GAS | PRIMARY METAL PRODUCTION | STEEL PRODUCTION | REHEAT FURNACES | |
50 | 46 | 119020AAE | 24289.8 | Dynegy Midwest Generation Inc | 4911 | 0001 | BOILER 5 PULV DRY TANGENTIAL | 01 | COAL FIRING | 10100202 | 8a | 3920 | 1910.9 | 5.3293 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM |
51 | 47 | 119020AAE | 24289.8 | Dynegy Midwest Generation Inc | 4911 | 0003 | BLR 4 PULV DRY BTM TANGENTIAL | 01 | COAL FIRING | 10100202 | 8a | 1030 | 456.6 | 1.5082 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
52 | 48 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0080 | UTILITY BOILER #15 (BLR-15) | 02 | RFG | 10200701 | 1a1 | 360 | 106.9 | 0.2929 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
53 | 49 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0081 | UTILITY BOILER #16 (BLR-16) | 02 | RFG | 10200701 | 1a1 | 249 | 149.4 | 0.4093 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
54 | 50 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0082 | UTILITY BOILER #17 (BLR-17) | 02 | RFG | 10200701 | 1a1 | 700 | 125.2 | 0.3431 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
55 | 51 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0083 | UTILITY BOILER #18 (BLR-18) | 01 | NATURAL GAS | 10200601 | 1a1 | 249 | 86.8 | 0.2378 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
56 | 52 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0083 | UTILITY BOILER #18 (BLR-18) | 02 | REFINERY FUEL GAS | 10200701 | 1a1 | 249 | 30.0 | 0.0821 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
57 | 53 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0614 | BOILER NO. 5 | 01 | NATURAL GAS COMBUSTION | 10200602 | 1a2 | 66 | 15.3 | 0.0419 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
58 | 54 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0004 | CAT REFORMER #1: FEED PREHEATER (HTR-CR1-H1) | 02 | RFG | 30600106 | 2a1 | 165 | 130.8 | 0.3584 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
59 | 55 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0005 | CAT REFORMER #1: FIRST INTERREACTOR HEATER (HTR-CR | 02 | RFG | 30600104 | 2a1 | 162 | 164.3 | 0.4502 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
60 | 56 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0014 | HYDROCRACKING UNIT: FRACTIONATOR REBOILER (HTR-HCU | 02 | RFG | 30600106 | 2a1 | 235 | 152.0 | 0.4164 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
61 | 57 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0018 | BENZENE EXTRACTION UNIT #2 (HTR-BEU-HM2) | 02 | RFG | 30600106 | 2a1 | 110 | 59.5 | 0.163 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
62 | 58 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0024 | DISTILLING UNIT: HTR-DU1-F301 | 02 | REFINERY GAS (RFG) | 30600106 | 2a1 | 120 | 138.8 | 0.3803 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
63 | 59 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0025 | DISTILLING UNIT: HTR-DU1-F302 | 01 | RFG | 30600106 | 2a1 | 200 | 226.9 | 0.6217 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
64 | 60 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0029 | DISTILLING UNIT: WEST CRUDE HEATER (HTR-DU2-F202) | 02 | REFINERY GAS (RFG) | 30600104 | 2a1 | 230 | 221.7 | 0.6073 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
65 | 61 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0030 | DISTILLING UNIT: EAST CRUDE HEATER (HTR-DU2-F203) | 01 | RFG | 30600106 | 2a1 | 230 | 226.6 | 0.6208 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
66 | 62 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0073 | ALKYLATION UNIT: HTR-ALKY-HM2 | 02 | RFG | 30600106 | 2a1 | 110 | 76.6 | 0.2099 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
67 | 63 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0084 | CAT REFORMER #2: CHARGE REHEATER (HTR-CR2-N) | 01 | RFG | 30600106 | 2a1 | 137.5 | 65.4 | 0.1792 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
68 | 64 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0086 | HEATER CR2-S (RFG FIRING) | 01 | FUEL COMBUSTION EMISSIONS RFG | 30600104 | 2a1 | 137.5 | 65.4 | 0.1792 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
69 | 65 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0091 | CAT REFORMER #3: CHARGE HEATER (HTR-CR3-H4) | 01 | RFG | 30600106 | 2a1 | 144.7 | 165.1 | 0.4524 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
70 | 66 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0092 | CAT REFORMER #3: FIRST INTERREACTOR HEATER (HTR-CR | 02 | RFG | 30600106 | 2a1 | 141 | 136.8 | 0.3748 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
71 | 67 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0094 | KEROSENE HYDROTREATER: KHT HEATER (HTR-KHT) | 01 | RFG | 30600106 | 2a1 | 109 | 106.2 | 0.2909 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
72 | 68 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0617 | DELAYED COKER UNIT HEATER H-20 | 02 | REFINERY FUEL GAS | 30600106 | 2a1 | 231 | 98.1 | 0.2688 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
73 | 69 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0623 | NO.2 CRUDE UNIT HEATER H-24 | 01 | NATURAL GAS COMBUSTION | 30600104 | 2a1 | 314 | 150.2 | 1.0018 | NATURAL GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
74 | 70 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0006 | CAT REFORMER #1: SECOND INTERREACTOR HEATER (HTR-C | 02 | RFG | 30600104 | 2a2 | 78 | 27.8 | 0.0761 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
75 | 71 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0007 | CAT REFORMER #1: STABILIZER REBOILER (HTR-CR1-H4) | 02 | RFG | 30600106 | 2a2 | 100 | 16.7 | 0.0458 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
76 | 72 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0009 | CAT REFORMER #1: THIRD INTERREACTOR HEATER (HTR-CR | 02 | RFG | 30600106 | 2a2 | 100 | 86.7 | 0.2375 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
77 | 73 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0017 | BENZENE EXTRACTION UNIT #1 (HTR-BEU-HM1) | 02 | RFG | 30600106 | 2a2 | 100 | 81.7 | 0.2239 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
78 | 74 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0031 | VACUUM FLASHER UNITS #1-3 (VF-1, -2, -3) | 01 | 30600104 | 2a2 | 273 | 140.2 | 0.384 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | ||
79 | 75 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0033 | RECTIFIED ABSORPTION UNIT: REBOILER HEATER (HTR-RA | 01 | RFG | 30600106 | 2a2 | 69 | 23.0 | 0.0629 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
80 | 76 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0036 | CRACKED ABSORPTION UNIT (HTR-CAU-ROSTILL) | 02 | RFG AND RFP | 30600106 | 2a2 | 95 | 30.0 | 0.0822 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
81 | 77 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0042 | CO HEATER (HTRR-CCU1-CO) | 01 | RFG | 30600104 | 2a2 | 17 | 91.9 | 0.2518 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
82 | 78 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0056 | CO HEATER (HTRR-CCU2-CO) | 01 | RFG | 30600104 | 2a2 | 80 | 82.1 | 0.2249 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
83 | 79 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0085 | HYDRODESULFURIZATION UNIT #1: CHARGE HEATER (HTR-H | 01 | RFG | 30600106 | 2a2 | 67.3 | 19.6 | 0.0536 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
84 | 80 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0088 | HYDRODESULFURIZATION UNIT #2: CHARGE HEATER (HTR-H | 01 | RFG | 30600106 | 2a2 | 81 | 26.2 | 0.0719 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
85 | 81 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0093 | CAT REFORMER #3: SECOND INTERREACTOR HEATER (HTR-C | 02 | RFG | 30600106 | 2a2 | 74 | 27.1 | 0.0742 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
86 | 82 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0154 | VACUUM FLASHER #2: EAST HEATER (HTR-VF2-F205) | 01 | RFG | 30600106 | 2a2 | 61 | 15.9 | 0.0436 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
87 | 83 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0155 | VACUUM FLASHER #1: NORTH HEATER (HTR-VF-1-NORTH) | 01 | 30600105 | 2a2 | 100 | 45.5 | 0.1247 | NATURAL GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | NATURAL GAS-FIRED | ||
88 | 84 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0156 | VACUUM FLASHER #1: SOUTH HEATER (HTR-VF-1-SOUTH) | 01 | 30600105 | 2a2 | 100 | 50.9 | 0.1394 | NATURAL GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | NATURAL GAS-FIRED | ||
89 | 85 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0044 | BOILER HOUSE 2: BOILER #11 - BLAST FURNACE DEPT | 04 | NATURAL GAS FIRING | 10200601 | 1a1 | 225 | 25.7 | 0.0654 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
90 | 86 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0044 | BOILER HOUSE 2: BOILER #11 - BLAST FURNACE DEPT | 01 | BLAST FURNACE GAS FIRING | 10200704 | 1a1 | 225 | 31.7 | 0.0454 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | BLAST FURNACE GAS | |
91 | 87 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0048 | BOILER HOUSE 2: BOILER #12 - BLAST FURNACE DEPT | 04 | NATURAL GAS FIRING | 10200601 | 1a1 | 225 | 24.8 | 0.0456 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
92 | 88 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0048 | BOILER HOUSE 2: BOILER #12 - BLAST FURNACE DEPT | 01 | BLAST FURNACE GAS FIRING | 10200704 | 1a1 | 225 | 21.2 | 0.0436 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | BLAST FURNACE GAS | |
93 | 89 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0048 | BOILER HOUSE 2: BOILER #12 - BLAST FURNACE DEPT | 02 | COKE OVEN GAS FIRING | 10200707 | 1a1 | 225 | 64.5 | 0.138 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | COKE OVEN GAS | |
94 | 90 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0041 | BOILER HOUSE 1: BOILERS 1 TO 7 | 01 | BLAST FURNACE GAS FIRING | 10200704 | 1a2 | 60 | 66.0 | 0.1502 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | BLAST FURNACE GAS | |
95 | 91 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0041 | BOILER HOUSE 1: BOILERS 1 TO 7 | 04 | NATURAL GAS FIRING | 10200601 | 1a2 | 420 | 44.6 | 0.1538 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
96 | 92 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0041 | BOILER HOUSE 1: BOILERS 1 TO 7 | 02 | COKE OVEN GAS FIRING | 10200707 | 1a2 | 559 | 134.2 | 0.4103 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | COKE OVEN GAS | |
97 | 93 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0042 | BOILER HOUSE 1: BOILERS 8 TO 10 | 04 | NATURAL GAS FIRING | 10200602 | 1a2 | 60 | 19.1 | 0.0659 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
98 | 94 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0042 | BOILER HOUSE 1: BOILERS 8 TO 10 | 01 | BLAST FURNACE GAS FIRING | 10200704 | 1a2 | 80 | 28.3 | 0.0644 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | BLAST FURNACE GAS | |
99 | 95 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0042 | BOILER HOUSE 1: BOILERS 8 TO 10 | 02 | COKE OVEN GAS FIRING | 10200707 | 1a2 | 60 | 57.5 | 0.1758 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | COKE OVEN GAS | |
100 | 96 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0015 | SLAB FURNACE #1 | 02 | COKE OVEN GAS FIRING | 39000689 | 7a | 321.8 | 84.9 | 0.4144 | PROCESS GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL |
101 | 97 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0015 | SLAB FURNACE #1 | 01 | NATURAL GAS FIRING | 39000689 | 7a | 321.8 | 266.2 | 0.7086 | NATURAL GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
102 | 98 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0018 | SLAB FURNACE #4 | 01 | NATURAL GAS FIRING | 39000689 | 7a | 495 | 113.8 | 0.9587 | NATURAL GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
103 | 99 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0122 | SLAB FURNACE #2 | 02 | COKE OVEN GAS FIRING | 39000689 | 7a | 322 | 82.2 | 0.3938 | PROCESS GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
104 | 100 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0122 | SLAB FURNACE #2 | 01 | NATURAL GAS FIRING | 39000689 | 7a | 322 | 149.2 | 0.6908 | NATURAL GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
105 | 101 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0123 | SLAB FURNACE #3 | 02 | COKE OVEN GAS FIRING | 39000689 | 7a | 322 | 101.6 | 0.4321 | PROCESS GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
106 | 102 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0123 | SLAB FURNACE #3 | 01 | NATURAL GAS FIRING | 39000689 | 7a | 322 | 162.8 | 0.7052 | NATURAL GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
107 | 103 | 157851AAA | 4875.6 | Dynegy Midwest Generation Inc | 4911 | 0001 | *BOILER #1 | 01 | COAL FIRING | 10100202 | 8a | 5890 | 1106.9 | 3.627 | COAL - SUBBITUMINOUS | ||||
108 | 104 | 157851AAA | 4875.6 | Dynegy Midwest Generation Inc | 4911 | 0002 | *'BOILER #2 | 01 | COAL FIRING | 10100202 | 8a | 5900 | 1495.3 | 3.547 | COAL - SUBBITUMINOUS | ||||
109 | 105 | 157851AAA | 4875.6 | Dynegy Midwest Generation Inc | 4911 | 0013 | *BOILER #3 | 01 | COAL FIRING | 10100202 | 8a | 5800 | 2271.6 | 6.624 | COAL - SUBBITUMINOUS | ||||
110 | 106 | 163045ADT | 168.3 | Elementis Pigments Inc | 2816 | 0061 | Erie City boiler | 01 | Natural gas | 10200601 | 1a1 | 135 | 41.4 | 0.258 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
111 | 107 | 163121AAY | 250.1 | Environmental Management Corp | 4961 | 0001 | BOILERS #1, #2 AND #3 | 01 | NATURAL GAS | 10200601 | 1a1 | 393 | 22.4 | 0.0553 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
112 | 108 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0037 | 430B-1: Auxiliary boiler | 01 | Refinery fuel gas | 10200701 | 1a1 | 396 | 120.5 | 0.3296 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | > 100 MBTU/HR | |
113 | 109 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0235 | 431B-20: North Plant Boiler | 01 | 10200501 | 1b1 | 249 | 22.3 | 0.0398 | DISTILLATE OIL #2 | EXTERNAL COMBUSTION BOILERS | DISTILLATE OIL | GRADES 1 AND 2 OIL | ||
114 | 110 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0003 | 111B-1A: Atmospheric heater | 01 | Refinery fuel gas | 30600104 | 2a1 | 376.5 | 46.4 | 0.1345 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
115 | 111 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0004 | 111B-1B: Atmospheric heater | 01 | Refinery fuel gas | 30600104 | 2a1 | 376.5 | 47.2 | 0.1362 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
116 | 112 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0005 | 111B-2: Crude vacuum heater | 01 | REFINERY FUEL GAS | 30600104 | 2a1 | 219.8 | 18.1 | 0.057 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
117 | 113 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0050 | 109B-62: Steam HC reformer heater | 01 | 30600104 | 2a1 | 113.3 | 55.2 | 0.1751 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | ||
118 | 114 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0070 | 123B-2: Feed preheater | 01 | REFINERY FUEL GAS | 30600106 | 2a1 | 121.2 | 54.5 | 0.1428 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
119 | 115 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0011 | 113B-1: Coker 1 charge heater | 01 | 30600104 | 2a2 | 88.8 | 16.0 | 0.0439 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | ||
120 | 116 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0012 | 113B-3: Coker 1 charge heater | 01 | 30600104 | 2a2 | 88.8 | 26.7 | 0.0721 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | ||
121 | 117 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0019 | 116B-1: Charge heater and stabilizer reboiler | 01 | 30600104 | 2a2 | 89.9 | 41.5 | 0.1198 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | ||
122 | 118 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0021 | 118B-1: Hot oil heater | 01 | 30600104 | 2a2 | 93.8 | 15.6 | 0.044 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | ||
123 | 119 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0048 | 108B-41: Process heater | 01 | 30600104 | 2a2 | 44 | 22.7 | 0.0614 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | ||
124 | 120 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0064 | 113B-2: Coker 1 charge heater | 01 | 30600106 | 2a2 | 88.8 | 16.4 | 0.045 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | ||
125 | 121 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0066 | 116B-2: Interheater and naphtha stripper reboiler | 01 | 30600106 | 2a2 | 84.2 | 24.9 | 0.0818 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | ||
126 | 122 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0073 | 123B-5: Reheat furnace | 01 | 30600106 | 2a2 | 42 | 17.5 | 0.0472 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | ||
127 | 123 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0074 | 125B-1 and 125B-2: Feed heater and stripper reboil | 01 | 30600106 | 2a2 | 100 | 32.0 | 0.0863 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | ||
128 | 124 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0002 | AUX BOILER | 03 | On hot standby (when cogen/coboiler operating) | 30600104 | 1a1 | 600 | 35.6 | 0.1013 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | > 100 MBTU/HR | |
129 | 125 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0018 | Crude unit heaters (#1B1A and #1B1B) | 01 | Gas fired | 30600104 | 2a1 | 778 | 288.5 | 0.7786 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
130 | 126 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0019 | Crude unit vacuum heater | 01 | Refinery gas fired | 30600106 | 2a1 | 277 | 117.5 | 0.3157 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
131 | 127 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0021 | Coker charge heaters (East and West) | 01 | 10200701 | 2a1 | 732 | 123.3 | 0.3185 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | ||
132 | 128 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0025 | Reformer charge heaters (2B3, 2B4, 2B5, 2B6) | 01 | 30600106 | 2a1 | 680 | 97.6 | 0.2593 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | ||
133 | 129 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0028 | Pretreat debut reboil 17-B-2 | 01 | 10200701 | 2a1 | 164 | 15.8 | 0.0454 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | ||
134 | 130 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0033 | CHD react charge heater 3B1 | 01 | Refinery gas | 30600104 | 2a1 | 158 | 41.4 | 0.1163 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
135 | 131 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0034 | CHD strip reboiler 3B2 | 01 | 10200701 | 2a1 | 129 | 42.6 | 0.1063 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | ||
136 | 132 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0038 | Alky isostrip reboiler heater 7B1 | 01 | Refinery gas | 10200701 | 2a1 | 171 | 34.1 | 0.1065 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
137 | 133 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0113 | Crude unit feed preheater 1-B3/13-B-4 | 01 | Gas feed | 30600106 | 2a1 | 240 | 30.7 | 0.0846 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
138 | 134 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0038 | Alky isostrip reboiler heater 7B1 | 02 | Oil fired (ASO) | 30600103 | 2b1 | 171 | 23.3 | 0.0696 | RESIDUAL OIL #4 | PETROLEUM INDUSTRY | PROCESS HEATERS | OIL FIRED | |
139 | 135 | 197800AAD | 198.2 | Loders Croklaan USA | 2079 | 0043 | JOHNSTON BOILER | 01 | 10200602 | 1a2 | 93.7 | 41.5 | 0.114 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | ||
140 | 136 | 197800ABZ | 1056.4 | Flint Hills Resources LP | 2865 | 0021 | 2 BOILERS (CB-703, CB-704) | 01 | 10200601 | 1a1 | 450 | 55.2 | 0.1628 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | ||
141 | 137 | 197800ABZ | 1056.4 | Flint Hills Resources LP | 2865 | 0119 | BOILER CB-706 | 01 | 10200601 | 1a1 | 370.2 | 17.8 | 0.0254 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | ||
142 | 138 | 197809AAC | 227.0 | Caterpillar Inc | 3531 | 0004 | Boiler #2 | 01 | Natural gas combustion | 10200601 | 1a1 | 112.6 | 16.1 | 0.0837 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
143 | 139 | 197809AAC | 227.0 | Caterpillar Inc | 3531 | 0005 | Boiler #3 | 01 | Natural gas combustion | 10200601 | 1a1 | 175 | 40.0 | 0.079 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
144 | 140 | 197809AAO | 60970.8 | Midwest Generation LLC | 4911 | 0009 | Joliet 9: Unit 6 cyclone boiler | 01 | Coal | 10100203 | 8a | 2886 | 5418.6 | 16.9076 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | CYCLONE FURNACE | |
145 | 141 | 197809AAO | 60970.8 | Midwest Generation LLC | 4911 | 0031 | Joliet 29: Unit 7 Boilers 71 and 72 | 01 | Coal | 10100202 | 8a | 4558 | 1760.7 | 6.0416 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
146 | 142 | 197809AAO | 60970.8 | Midwest Generation LLC | 4911 | 0033 | Joliet 29: Unit 8 Boilers 81 and 82 | 01 | Coal | 10100202 | 8a | 3193 | 1879.2 | 5.9909 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
147 | 143 | 197810AAK | 18014.4 | Will County Electric Generating Station | 4911 | 0010 | UNIT #1 BOILER CYCLONE | 02 | COAL FIRING | 10100223 | 8a | 1728 | 2679.0 | 9.5894 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | CYCLONE FURNACE | |
148 | 144 | 197810AAK | 18014.4 | Will County Electric Generating Station | 4911 | 0012 | UNIT #2 BOILER CYCLONE | 02 | COAL FIRED | 10100223 | 8a | 1712 | 2531.0 | 9.1506 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | CYCLONE FURNACE | |
149 | 145 | 197810AAK | 18014.4 | Will County Electric Generating Station | 4911 | 0014 | UNIT #3 BOILER PULV. DRY BOTTOM - TANGENTIALY FIRE | 02 | COAL FIRED | 10100222 | 8a | 2709 | 873.1 | 2.7744 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
150 | 146 | 197810AAK | 18014.4 | Will County Electric Generating Station | 4911 | 0016 | UNIT #4 BOILER PULV. DRY BOTTOM - TANGENTIALY FIRE | 02 | COAL FIRED | 10100222 | 8a | 5016 | 1690.8 | 6.0994 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
151 | All Sources in Chicago and Metro-East NAAs, Total | 90419 | 44625 | 143 |
A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Table E-1: Boilers Subject to NOx SIP Call Regulations (>250 mmBtu/hour) | |||||||||||||||||
2 | Mydocument/TSD/NOx RACT-Attachments.xls | |||||||||||||||||
3 | ||||||||||||||||||
4 | Boilers > 250 mmBtu/hour in Chicago NAA | |||||||||||||||||
5 | Facility ID | Source PTE TPY NOx | Facility Name | SIC | Emission Unit ID | Emission Point Description | Mode ID | Mode Description | SCC # | Emission Unit category | Heat Input Capacity mmbtu/hr | 2005 NOx Emissions tpy | Unit Typical Ozone Season NOx tons/day | Fuel | descr1 | descr3 | descr4 | |
6 | Industrial Boilers >250 mmBtu/hour in Chicago NAA | |||||||||||||||||
7 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0046 | UTILITIES - BOILER #5 (A-23-93) | 01 | 10200601 | 1a1 | 312.5 | 39.2 | 0.064 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | ||
8 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0160 | UTILITIES - BOILER #6 (A23-144) | 01 | 10200601 | 1a1 | 600 | 16.8 | 0.0384 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | ||
9 | 097811AAC | 826.8 | Naval Training Center | 9711 | 0011 | BUILDING 11: BOILERS #5 AND #6 | 01 | NATURAL GAS COMBUSTION | 10200601 | 1a1 | 680 | 94.0 | 0.0341 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
10 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0037 | 430B-1: Auxiliary boiler | 01 | Refinery fuel gas | 10200701 | 1a1 | 396 | 120.5 | 0.3296 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | > 100 MBTU/HR | |
11 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0002 | AUX BOILER | 03 | On hot standby (when cogen/coboiler operating) | 30600104 | 1a1 | 600 | 35.6 | 0.1013 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | > 100 MBTU/HR | |
12 | 197800ABZ | 1056.4 | Flint Hills Resources LP | 2865 | 0119 | BOILER CB-706 | 01 | 10200601 | 1a1 | 370.2 | 17.8 | 0.0254 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | ||
13 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0041 | UTILITIES - BOILER #1 (A-23-92) | 01 | 10200202 | 1e2 | 332.5 | 760.7 | 3.1979 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | ||
14 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0042 | UTILITIES - BOILER #2 (A-23-92) | 01 | 10200202 | 1e2 | 332.5 | 796.9 | 3.2401 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | ||
15 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0045 | UTILITIES - BOILER #3 (A-23-93) | 01 | 10200202 | 1e2 | 332.5 | 772.6 | 2.4953 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | ||
16 | EGU Boilers >250 mmBtu/hour in Chicago NAA | |||||||||||||||||
17 | 031600AIN | 32962.1 | Crawford Electric Generating Station | 4911 | 0013 | Unit 7 | 01 | Coal | 10100226 | 8a | 2342 | 873.9 | 2.746 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
18 | 031600AIN | 32962.1 | Crawford Electric Generating Station | 4911 | 0016 | Unit 8 | 01 | Coal | 10100226 | 8a | 3556 | 1375.0 | 4.1789 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
19 | 031600AMI | 13414.4 | Fisk Electric Generating Station | 4911 | 0010 | FISK UNIT #19 | 01 | COAL FIRING | 10100226 | 8a | 2896 | 1125.6 | 3.8275 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
20 | 097190AAC | 47103.0 | Waukegan Electric Generating Station | 4911 | 0031 | UNIT #6 BOILER | 01 | COAL FIRING | 10100203 | 8a | 1024 | 1627.3 | 5.9705 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | CYCLONE FURNACE | |
21 | 097190AAC | 47103.0 | Waukegan Electric Generating Station | 4911 | 0033 | UNIT #8 BOILER | 01 | COAL FIRING | 10100226 | 8a | 3271 | 1595.4 | 4.6723 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
22 | 097190AAC | 47103.0 | Waukegan Electric Generating Station | 4911 | 0036 | UNIT #7 BOILER | 01 | COAL FIRING | 10100226 | 8a | 2911 | 1397.9 | 4.2667 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
23 | 197809AAO | 60970.8 | Midwest Generation LLC | 4911 | 0009 | Joliet 9: Unit 6 cyclone boiler | 01 | Coal | 10100203 | 8a | 2886 | 5418.6 | 16.9076 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | CYCLONE FURNACE | |
24 | 197809AAO | 60970.8 | Midwest Generation LLC | 4911 | 0031 | Joliet 29: Unit 7 Boilers 71 and 72 | 01 | Coal | 10100202 | 8a | 4558 | 1760.7 | 6.0416 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
25 | 197809AAO | 60970.8 | Midwest Generation LLC | 4911 | 0033 | Joliet 29: Unit 8 Boilers 81 and 82 | 01 | Coal | 10100202 | 8a | 3193 | 1879.2 | 5.9909 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
26 | 197810AAK | 18014.4 | Will County Electric Generating Station | 4911 | 0010 | UNIT #1 BOILER CYCLONE | 02 | COAL FIRING | 10100223 | 8a | 1728 | 2679.0 | 9.5894 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | CYCLONE FURNACE | |
27 | 197810AAK | 18014.4 | Will County Electric Generating Station | 4911 | 0012 | UNIT #2 BOILER CYCLONE | 02 | COAL FIRED | 10100223 | 8a | 1712 | 2531.0 | 9.1506 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | CYCLONE FURNACE | |
28 | 197810AAK | 18014.4 | Will County Electric Generating Station | 4911 | 0014 | UNIT #3 BOILER PULV. DRY BOTTOM - TANGENTIALY FIRE | 02 | COAL FIRED | 10100222 | 8a | 2709 | 873.1 | 2.7744 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
29 | 197810AAK | 18014.4 | Will County Electric Generating Station | 4911 | 0016 | UNIT #4 BOILER PULV. DRY BOTTOM - TANGENTIALY FIRE | 02 | COAL FIRED | 10100222 | 8a | 5016 | 1690.8 | 6.0994 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
30 | ||||||||||||||||||
31 | ||||||||||||||||||
32 | Boilers > 250 mmBtu/hour in Metro-East NAA | |||||||||||||||||
33 | Industrial Boilers >250 mmBtu/hour in Metro-East NAA | |||||||||||||||||
34 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0080 | UTILITY BOILER #15 (BLR-15) | 02 | RFG | 10200701 | 1a1 | 360 | 106.9 | 0.2929 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
35 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0082 | UTILITY BOILER #17 (BLR-17) | 02 | RFG | 10200701 | 1a1 | 700 | 125.2 | 0.3431 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
36 | EGU Boilers >250 mmBtu/hour in Metro-East NAA | |||||||||||||||||
37 | 119020AAE | 24289.8 | Dynegy Midwest Generation Inc | 4911 | 0001 | BOILER 5 PULV DRY TANGENTIAL | 01 | COAL FIRING | 10100202 | 8a | 3920 | 1910.9 | 5.3293 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
38 | 119020AAE | 24289.8 | Dynegy Midwest Generation Inc | 4911 | 0003 | BLR 4 PULV DRY BTM TANGENTIAL | 01 | COAL FIRING | 10100202 | 8a | 1030 | 456.6 | 1.5082 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
39 | 157851AAA | 4875.6 | Dynegy Midwest Generation Inc | 4911 | 0001 | BOILER #1 | 01 | COAL FIRING | 10100202 | 8a | 5890 | 1106.9 | 3.627 | COAL - SUBBITUMINOUS | ||||
40 | 157851AAA | 4875.6 | Dynegy Midwest Generation Inc | 4911 | 0002 | BOILER #2 | 01 | COAL FIRING | 10100202 | 8a | 5900 | 1495.3 | 3.547 | COAL - SUBBITUMINOUS | ||||
41 | 157851AAA | 4875.6 | Dynegy Midwest Generation Inc | 4911 | 0013 | BOILER #3 | 01 | COAL FIRING | 10100202 | 8a | 5800 | 2271.6 | 6.624 | COAL - SUBBITUMINOUS |
A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Table F-1: NOx Reductions from the Application of NOx RACT in Chicago NAA | ||||||||||||||||||||||
2 | Mydocument/TSD/NOx RACT-Attachments.xls | ||||||||||||||||||||||
3 | |||||||||||||||||||||||
4 | Facility ID | Source PTE TPY NOx | Facility Name | SIC | Emission Unit ID | Emission Point Description | Mode ID | Mode Description | SCC # | Emission Unit category | Heat Input Capacity mmbtu/hr | 2005 NOx Emissions tpy | Estimated NOx RACT Reduction , % | Estimated Controlled NOx tpy | Estimated Nox Reduction Tons | Unit Typical Ozone Season NOx tons/day | Estimated Ozone Season Controlled NOx, TPD | Estimated Ozone season NOx Reduction, TPD | Fuel | descr1 | descr3 | descr4 | |
5 | 031003ADA | 516.7 | Alsip Paper Condominium Assn | 4931 | 0004 | BOILERS #1 AND #2 | 01 | 10200601 | 1a1 | 310 | 173.1 | 69.2% | 53.3 | 119.85 | 0.2184 | 0.07 | 0.151 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | ||
6 | 031012AAO | 139.6 | Nalco Co | 2899 | 0049 | BOILER #1 | 01 | NATURAL GAS COMBUSTION | 10200601 | 1a1 | 114.6 | 17.9 | 69.2% | 5.5 | 12.41 | 0.0656 | 0.02 | 0.05 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
7 | 031012AAO | 139.6 | Nalco Co | 2899 | 0061 | BOILER #2 | 01 | NATURAL GAS COMBUSTION | 10200601 | 1a1 | 124 | 42.3 | 69.2% | 13.0 | 29.26 | 0.2875 | 0.09 | 0.20 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
8 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0046 | UTILITIES - BOILER #5 (A-23-93) | 01 | 10200601 | 1a1 | 312.5 | 39.2 | 69.2% | 12.0 | 27.11 | 0.064 | 0.02 | 0.04 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | ||
9 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0160 | UTILITIES - BOILER #6 (A23-144) | 01 | 10200601 | 1a1 | 600 | 16.8 | 69.2% | 5.2 | 11.66 | 0.0384 | 0.01 | 0.03 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | ||
10 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0233 | UTILITIES - BOILER #7 | 01 | 10200601 | 1a1 | 240 | 30.5 | 69.2% | 9.4 | 21.09 | 0.087 | 0.03 | 0.06 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | ||
11 | 031081AEQ | 286.5 | Northwestern University | 8221 | 0001 | 3 EC Boilers (#1, 2 and 3 - Central Utility Plant) | 01 | 10300601 | 1a1 | 556 | 156.7 | 69.2% | 48.2 | 108.46 | 0.4436 | 0.14 | 0.31 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MMBTU/HR | ||
12 | 031600FLT | 204.3 | University of Chicago | 8221 | 0001 | BOILERS 1-4 | 01 | NATURAL GAS FIRING | 10200601 | 1a1 | 782 | 63.5 | 69.2% | 19.5 | 43.94 | 0.1142 | 0.04 | 0.08 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
13 | 031817AAL | 292.7 | VA Edward Hines Jr Hospital | 8062 | 0004 | BOILERS 1-4 | 01 | NATURAL GAS | 10300602 | 1a1 | 200 | 17.8 | 69.2% | 5.5 | 12.35 | 0.0231 | 0.01 | 0.02 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
14 | 043802AAA | 727.9 | Argonne National Laboratory | 8733 | 0001 | Boiler #1 | 01 | Natural Gas Combustion | 10300601 | 1a1 | 106 | 25.2 | 69.2% | 7.8 | 17.47 | 0.082 | 0.03 | 0.06 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MMBTU/HR | |
15 | 043802AAA | 727.9 | Argonne National Laboratory | 8733 | 0003 | Boiler #3 | 01 | Natural Gas Combustion | 10300601 | 1a1 | 106 | 19.4 | 69.2% | 6.0 | 13.42 | 0 | 0.00 | 0.00 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MMBTU/HR | |
16 | 043802AAA | 727.9 | Argonne National Laboratory | 8733 | 0004 | Boiler #4 | 01 | Natural Gas Combustion | 10300601 | 1a1 | 106 | 19.0 | 69.2% | 5.8 | 13.15 | 0 | 0.00 | 0.00 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MMBTU/HR | |
17 | 063800AAC | 628.1 | Equistar Chemicals LP | 2869 | 0025 | ETHYLENE PLANT - STEAM SUPERHEATER | 01 | 10200799 | 1a1 | 141 | 47.2 | 69.2% | 14.5 | 32.69 | 0.1294 | 0.04 | 0.09 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | > 100 MBTU/HR | ||
18 | 089800AAH | 711.8 | Dial Corp | 2841 | 0075 | BOILERS #1 AND #2 | 01 | NATURAL GAS | 10200601 | 1a1 | 210 | 124.1 | 69.2% | 38.2 | 85.89 | 0.3475 | 0.11 | 0.24 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
19 | 097125AAA | 582.3 | Abbott Laboratories | 2834 | 0858 | BOILER #10 NC (CED) | 01 | NATURAL GAS | 10200601 | 1a1 | 220 | 24.7 | 69.2% | 7.6 | 17.10 | 0.0761 | 0.02 | 0.05 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
20 | 097811AAC | 826.8 | Naval Training Center | 9711 | 0011 | BUILDING 11: BOILERS #5 AND #6 | 01 | NATURAL GAS COMBUSTION | 10200601 | 1a1 | 680 | 94.0 | 69.2% | 28.9 | 65.06 | 0.0341 | 0.01 | 0.02 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
21 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0037 | 430B-1: Auxiliary boiler | 01 | Refinery fuel gas | 10200701 | 1a1 | 396 | 120.5 | 69.2% | 37.1 | 83.42 | 0.3296 | 0.10 | 0.23 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | > 100 MBTU/HR | |
22 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0002 | AUX BOILER | 03 | On hot standby (when cogen/coboiler operating) | 30600104 | 1a1 | 600 | 35.6 | 69.2% | 11.0 | 24.65 | 0.1013 | 0.03 | 0.07 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | > 100 MBTU/HR | |
23 | 197800ABZ | 1056.4 | Flint Hills Resources LP | 2865 | 0021 | 2 BOILERS (CB-703, CB-704) | 01 | 10200601 | 1a1 | 450 | 55.2 | 69.2% | 17.0 | 38.24 | 0.1628 | 0.05 | 0.11 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | ||
24 | 197800ABZ | 1056.4 | Flint Hills Resources LP | 2865 | 0119 | BOILER CB-706 | 01 | 10200601 | 1a1 | 370.2 | 17.8 | 69.2% | 5.5 | 12.30 | 0.0254 | 0.01 | 0.02 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | ||
25 | 197809AAC | 227.0 | Caterpillar Inc | 3531 | 0004 | Boiler #2 | 01 | Natural gas combustion | 10200601 | 1a1 | 112.6 | 16.1 | 69.2% | 5.0 | 11.15 | 0.0837 | 0.03 | 0.06 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
26 | 197809AAC | 227.0 | Caterpillar Inc | 3531 | 0005 | Boiler #3 | 01 | Natural gas combustion | 10200601 | 1a1 | 175 | 40.0 | 69.2% | 12.3 | 27.66 | 0.079 | 0.02 | 0.05 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
27 | Gaseous Fuel-fired Boilers >100 mmBtu/hr, Total | 6911.9 | 1196.5 | 69.2% | 368.2 | 828.3 | 2.79 | 0.86 | 1.93 | ||||||||||||||
28 | 031600CAO | 221.5 | Kraft Foods Global Inc | 2052 | 0107 | BOILER #5 | 01 | NATURAL GAS | 10200602 | 1a2 | 63.3 | 20.7 | 15.0% | 17.6 | 3.11 | 0.012 | 0.01 | 0.00 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
29 | 031600DDJ | 175.6 | National Railroad Passenger Corp | 4013 | 0001 | BOILER #1 | 01 | NATURAL GAS FIRING | 10200602 | 1a2 | 77.4 | 16.0 | 15.0% | 13.6 | 2.40 | 0 | 0.00 | 0.00 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
30 | 197800AAD | 198.2 | Loders Croklaan USA | 2079 | 0043 | JOHNSTON BOILER | 01 | 10200602 | 1a2 | 93.7 | 41.5 | 15.0% | 35.3 | 6.23 | 0.114 | 0.10 | 0.02 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | ||
31 | 031600FMX | 114.3 | Northwestern Memorial Hospital | 8062 | 0002 | 5 Boilers | 01 | Natural gas combustion | 10300602 | 1a2 | 126 | 31.8 | 15.0% | 27.0 | 4.77 | 0.0874 | 0.07 | 0.01 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
32 | 031600FQP | 202.5 | Chicago - Dept of Aviation | 4581 | 0003 | 8 HIGH TEMPERATURE WATER GENERATORS (HTWG-4001 - 4 | 01 | NATURAL GAS COMBUSTION | 10200602 | 1a2 | 758.6 | 26.0 | 15.0% | 22.1 | 3.89 | 0.3708 | 0.32 | 0.06 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
33 | 031817AAB | 108.9 | Loyola University Medical Center | 8221 | 0017 | BOILERS 2, 3 AND 4 | 01 | 10300602 | 1a2 | 154.9 | 20.6 | 15.0% | 17.5 | 3.09 | 0.0481 | 0.04 | 0.01 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | ||
34 | Gaseous fuel-fired Boilers < =100 mmBtu/hr, Total | 1273.9 | 156.6 | 15.0% | 133.1 | 23.5 | 0.63 | 0.54 | 0.09 | ||||||||||||||
35 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0235 | 431B-20: North Plant Boiler | 01 | 10200501 | 1b1 | 249 | 22.3 | 52.4% | 10.6 | 11.69 | 0.0398 | 0.02 | 0.02 | DISTILLATE OIL #2 | EXTERNAL COMBUSTION BOILERS | DISTILLATE OIL | GRADES 1 AND 2 OIL | ||
36 | Dist. oil Boilers >100 mmBtu/hr, Total | 249 | 22.3 | 52.4% | 10.6 | 11.7 | 0.040 | 0.02 | 0.02 | ||||||||||||||
37 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0041 | UTILITIES - BOILER #1 (A-23-92) | 01 | 10200202 | 1e2 | 332.5 | 760.7 | 73.9% | 198.4 | 562.26 | 3.1979 | 0.83 | 2.36 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | ||
38 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0042 | UTILITIES - BOILER #2 (A-23-92) | 01 | 10200202 | 1e2 | 332.5 | 796.9 | 73.9% | 207.9 | 588.98 | 3.2401 | 0.85 | 2.39 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | ||
39 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0045 | UTILITIES - BOILER #3 (A-23-93) | 01 | 10200202 | 1e2 | 332.5 | 772.6 | 73.9% | 201.6 | 571.08 | 2.4953 | 0.65 | 1.84 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | ||
40 | Solid Fuel Boilers >250 mmbtu/hr, Total | 997.5 | 2330.2 | 73.9% | 607.9 | 1722.3 | 8.93 | 2.33 | 6.60 | ||||||||||||||
41 | 043802AAA | 727.9 | Argonne National Laboratory | 8733 | 0005 | Boiler #5 | 04 | Coal Firing | 10300205 | 1e3 | 212 | 21.6 | 63.8% | 7.8 | 13.8 | 0 | 0.00 | 0.00 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: WET BOTTOM | |
42 | Solid Fuel <=250, >100 mmbtu/hr, Total | 212 | 21.6 | 63.8% | 7.8 | 13.8 | 0.0 | 0.0 | 0.0 | ||||||||||||||
43 | 063800AAE | 491.0 | Akzo Nobel Surface Chemistry LLC | 2869 | 0033 | STEAM BOILER J-090 (NEBRASKA) | 03 | PITCH FUEL FIRED | 10201201 | 1e4 | 40.2 | 37.1 | 15.0% | 31.6 | 5.57 | 0.2271 | 0.19 | 0.03 | OTHER | EXTERNAL COMBUSTION BOILERS | SOLID WASTE | SPECIFY WASTE MATERIAL IN COMMENTS | |
44 | 097125AAA | 582.3 | Abbott Laboratories | 2834 | 0070 | BOILER #5NC (TT-16) (CED) | 01 | COAL FIRED | 10100204 | 1e4 | 85 | 85.5 | 15.0% | 72.7 | 12.83 | 0.2898 | 0.25 | 0.04 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | SPREADER STOKER | |
45 | 097125AAA | 582.3 | Abbott Laboratories | 2834 | 0242 | BOILER #6 NC (TT-20) (CED) | 01 | COAL FIRED | 10100204 | 1e4 | 85 | 77.1 | 15.0% | 65.5 | 11.56 | 0.2743 | 0.23 | 0.04 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | SPREADER STOKER | |
46 | 097809AAD | 1629.2 | Abbott Laboratories | 2834 | 0006 | Boiler 4AP | 01 | Coal fired | 10200204 | 1e4 | 83 | 147.8 | 15.0% | 125.6 | 22.17 | 0.4492 | 0.38 | 0.07 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | SPREADER STOKER | |
47 | 097809AAD | 1629.2 | Abbott Laboratories | 2834 | 0103 | Boiler #5AP | 01 | Coal fired | 10200204 | 1e4 | 83 | 129.2 | 15.0% | 109.8 | 19.38 | 0.3739 | 0.32 | 0.06 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | SPREADER STOKER | |
48 | Solid Fuel Boilers <=100 mmbtu/hr, Total | 376.2 | 476.7 | 15.0% | 405.2 | 71.5 | 1.61 | 1.37 | 0.24 | ||||||||||||||
49 | 063800AAC | 628.1 | Equistar Chemicals LP | 2869 | 0026 | ETHYLENE PLANT - 14 CRACKING FURNACES (101-114) | 01 | 30600104 | 2a1 | 1277 | 357.3 | 28.6% | 255.2 | 102.07 | 0.9788 | 0.70 | 0.28 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | ||
50 | 063800AAM | 243.8 | Aux Sable Liquid Products | 1321 | 0019 | Heaters 1H101, 2H101, H301, H601, H602, 501A, 501B | 01 | 39000699 | 2a1 | 859.3 | 156.1 | 28.6% | 111.5 | 44.59 | 0.4359 | 0.31 | 0.12 | NATURAL GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL |
51 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0003 | 111B-1A: Atmospheric heater | 01 | Refinery fuel gas | 30600104 | 2a1 | 376.5 | 46.4 | 28.6% | 33.1 | 13.25 | 0.1345 | 0.10 | 0.04 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
52 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0004 | 111B-1B: Atmospheric heater | 01 | Refinery fuel gas | 30600104 | 2a1 | 376.5 | 47.2 | 28.6% | 33.7 | 13.47 | 0.1362 | 0.10 | 0.04 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
53 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0005 | 111B-2: Crude vacuum heater | 01 | REFINERY FUEL GAS | 30600104 | 2a1 | 219.8 | 18.1 | 28.6% | 12.9 | 5.17 | 0.057 | 0.04 | 0.02 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
54 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0050 | 109B-62: Steam HC reformer heater | 01 | 30600104 | 2a1 | 113.3 | 55.2 | 28.6% | 39.5 | 15.78 | 0.1751 | 0.13 | 0.05 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | ||
55 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0070 | 123B-2: Feed preheater | 01 | REFINERY FUEL GAS | 30600106 | 2a1 | 121.2 | 54.5 | 28.6% | 38.9 | 15.56 | 0.1428 | 0.10 | 0.04 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
56 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0018 | Crude unit heaters (#1B1A and #1B1B) | 01 | Gas fired | 30600104 | 2a1 | 778 | 288.5 | 28.6% | 206.0 | 82.42 | 0.7786 | 0.56 | 0.22 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
57 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0019 | Crude unit vacuum heater | 01 | Refinery gas fired | 30600106 | 2a1 | 277 | 117.5 | 28.6% | 83.9 | 33.58 | 0.3157 | 0.23 | 0.09 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
58 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0021 | Coker charge heaters (East and West) | 01 | 10200701 | 2a1 | 732 | 123.3 | 28.6% | 88.1 | 35.23 | 0.3185 | 0.23 | 0.09 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | ||
59 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0025 | Reformer charge heaters (2B3, 2B4, 2B5, 2B6) | 01 | 30600106 | 2a1 | 680 | 97.6 | 28.6% | 69.7 | 27.89 | 0.2593 | 0.19 | 0.07 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | ||
60 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0028 | Pretreat debut reboil 17-B-2 | 01 | 10200701 | 2a1 | 164 | 15.8 | 28.6% | 11.3 | 4.50 | 0.0454 | 0.03 | 0.01 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | ||
61 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0033 | CHD react charge heater 3B1 | 01 | Refinery gas | 30600104 | 2a1 | 158 | 41.4 | 28.6% | 29.6 | 11.83 | 0.1163 | 0.08 | 0.03 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
62 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0034 | CHD strip reboiler 3B2 | 01 | 10200701 | 2a1 | 129 | 42.6 | 28.6% | 30.4 | 12.16 | 0.1063 | 0.08 | 0.03 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | ||
63 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0038 | Alky isostrip reboiler heater 7B1 | 01 | Refinery gas | 10200701 | 2a1 | 171 | 34.1 | 28.6% | 24.3 | 9.73 | 0.1065 | 0.08 | 0.03 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
64 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0113 | Crude unit feed preheater 1-B3/13-B-4 | 01 | Gas feed | 30600106 | 2a1 | 240 | 30.7 | 28.6% | 21.9 | 8.77 | 0.0846 | 0.06 | 0.02 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
65 | Process Htrs Gas fired >100 mmBtu/hr, Total | 6672.6 | 1526.0 | 28.6% | 1090.0 | 436.0 | 4.19 | 2.99 | 1.20 | ||||||||||||||
66 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0011 | 113B-1: Coker 1 charge heater | 01 | 30600104 | 2a2 | 88.8 | 16.0 | 15.0% | 13.6 | 2.40 | 0.0439 | 0.04 | 0.01 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | ||
67 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0012 | 113B-3: Coker 1 charge heater | 01 | 30600104 | 2a2 | 88.8 | 26.7 | 15.0% | 22.7 | 4.00 | 0.0721 | 0.06 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | ||
68 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0019 | 116B-1: Charge heater and stabilizer reboiler | 01 | 30600104 | 2a2 | 89.9 | 41.5 | 15.0% | 35.3 | 6.23 | 0.1198 | 0.10 | 0.02 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | ||
69 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0021 | 118B-1: Hot oil heater | 01 | 30600104 | 2a2 | 93.8 | 15.6 | 15.0% | 13.3 | 2.35 | 0.044 | 0.04 | 0.01 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | ||
70 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0048 | 108B-41: Process heater | 01 | 30600104 | 2a2 | 44 | 22.7 | 15.0% | 19.3 | 3.41 | 0.0614 | 0.05 | 0.01 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | ||
71 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0064 | 113B-2: Coker 1 charge heater | 01 | 30600106 | 2a2 | 88.8 | 16.4 | 15.0% | 13.9 | 2.46 | 0.045 | 0.04 | 0.01 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | ||
72 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0066 | 116B-2: Interheater and naphtha stripper reboiler | 01 | 30600106 | 2a2 | 84.2 | 24.9 | 15.0% | 21.1 | 3.73 | 0.0818 | 0.07 | 0.01 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | ||
73 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0073 | 123B-5: Reheat furnace | 01 | 30600106 | 2a2 | 42 | 17.5 | 15.0% | 14.9 | 2.63 | 0.0472 | 0.04 | 0.01 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | ||
74 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0074 | 125B-1 and 125B-2: Feed heater and stripper reboil | 01 | 30600106 | 2a2 | 100 | 32.0 | 15.0% | 27.2 | 4.80 | 0.0863 | 0.07 | 0.01 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | ||
75 | Process Htrs Gas-fired< =100 mmBtu/hr, Total | 720.3 | 213.3 | 15.0% | 181.3 | 32.0 | 0.60 | 0.51 | 0.09 | ||||||||||||||
76 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0038 | Alky isostrip reboiler heater 7B1 | 02 | Oil fired (ASO) | 30600103 | 2b1 | 171 | 23.3 | 76.2% | 5.5 | 17.74 | 0.0696 | 0.02 | 0.05 | RESIDUAL OIL #4 | PETROLEUM INDUSTRY | PROCESS HEATERS | OIL FIRED | |
77 | Process Htrs, Residual Oil-fired, >100 mmBtu/hr, Total | 171 | 23.3 | 76.2% | 5.5 | 17.7 | 0.07 | 0.02 | 0.05 | ||||||||||||||
78 | 063800AAE | 491.0 | Akzo Nobel Surface Chemistry LLC | 2869 | 0017 | DOWTHERM BOILER | 02 | PITCH FUEL FIRED | 10201201 | 2c3 | 17 | 26.5 | 15.0% | 22.5 | 3.97 | 0.103 | 0.09 | 0.02 | OTHER | EXTERNAL COMBUSTION BOILERS | SOLID WASTE | SPECIFY WASTE MATERIAL IN COMMENTS | |
79 | Process Htrs, Other Oil-fired,100 mmBtu/hr, Total | 17 | 26.5 | 22.5 | 4.0 | 0.10 | 0.09 | 0.02 | |||||||||||||||
80 | 031045AAJ | 316.1 | Kimble Glass Inc | 0006 | GLASS MELTING FURNACE B | 01 | 30501402 | 3 | 25 | 50.8 | 50.0% | 25.4 | 25.38 | 0.14 | 0.07 | 0.07 | |||||||
81 | 031069AAI | 1113.0 | Saint-Gobain Containers Inc | 0013 | 3 GLASS MELTING FURNACES (1, 2 AND 3) | 01 | 30501402 | 3 | 120 | 681.2 | 50.0% | 340.6 | 340.57 | 1.87584 | 0.94 | 0.94 | NATURAL GAS | ||||||
82 | Glass melting Furnaces, Total | 145 | 731.9 | 50.0% | 366.0 | 366.0 | 2.02 | 1.01 | 1.01 | ||||||||||||||
83 | 031600ADY | 1338.7 | Carmeuse Lime Inc | 3274 | 0024 | ROTARY KILN 4 | 01 | 30501605 | 5a | 155.6 | 250.4 | 30.0% | 175.2 | 75.11 | 0.9868 | 0.69 | 0.30 | PROPANE | MINERAL PRODUCTS | LIME MANUFACTURE | CALCIMATIC KILN | ||
84 | 031600ADY | 1338.7 | Carmeuse Lime Inc | 3274 | 0028 | ROTARY KILN 5 | 01 | 30501604 | 5a | 433.3 | 484.1 | 30.0% | 338.8 | 145.22 | 1.554 | 1.09 | 0.47 | PROPANE | MINERAL PRODUCTS | LIME MANUFACTURE | CALCINING: ROTARY KILN | ||
85 | Lime Kilns, Total | 588.9 | 734.4 | 30.0% | 514.1 | 220.3 | 2.54 | 1.78 | 0.76 | ||||||||||||||
86 | 031258ABR | 516.7 | Mittal Steel USA - Riverdale Inc | 3312 | 0184 | TUNNEL FURNACE | 01 | 30390003 | 7b | 123 | 44.1 | 60.0% | 17.6 | 26.47 | 0.1502 | 0.06 | 0.09 | NATURAL GAS | PRIMARY METAL PRODUCTION | PROCESS HEATERS | NATURAL GAS | ||
87 | Annealing Furnace, Iron and Steel, Total | 123.0 | 44.1 | 60.0% | 17.6 | 26.5 | 0.15 | 0.06 | 0.09 | ||||||||||||||
88 | 031600AIN | 32962.1 | Crawford Electric Generating Station | 4911 | 0013 | Unit 7 | 01 | Coal | 10100226 | 8a | 2342 | 873.9 | 32.3% | 591.3 | 282.53 | 2.746 | 1.86 | 0.89 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
89 | 031600AIN | 32962.1 | Crawford Electric Generating Station | 4911 | 0016 | Unit 8 | 01 | Coal | 10100226 | 8a | 3556 | 1375.0 | 39.6% | 830.5 | 544.46 | 4.1789 | 2.52 | 1.65 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
90 | 031600AMI | 13414.4 | Fisk Electric Generating Station | 4911 | 0010 | FISK UNIT #19 | 01 | COAL FIRING | 10100226 | 8a | 2896 | 1125.6 | 34.8% | 734.1 | 391.52 | 3.8275 | 2.50 | 1.33 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
91 | 097190AAC | 47103.0 | Waukegan Electric Generating Station | 4911 | 0031 | UNIT #6 BOILER | 01 | COAL FIRING | 10100203 | 8a | 1024 | 1627.3 | 86.6% | 218.6 | 1408.72 | 5.9705 | 0.80 | 5.17 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | CYCLONE FURNACE | |
92 | 097190AAC | 47103.0 | Waukegan Electric Generating Station | 4911 | 0033 | UNIT #8 BOILER | 01 | COAL FIRING | 10100226 | 8a | 3271 | 1595.4 | 33.8% | 1055.8 | 539.62 | 4.6723 | 3.09 | 1.58 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
93 | 097190AAC | 47103.0 | Waukegan Electric Generating Station | 4911 | 0036 | UNIT #7 BOILER | 01 | COAL FIRING | 10100226 | 8a | 2911 | 1397.9 | 34.8% | 911.6 | 486.21 | 4.2667 | 2.78 | 1.48 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
94 | 197809AAO | 60970.8 | Midwest Generation LLC | 4911 | 0009 | Joliet 9: Unit 6 cyclone boiler | 01 | Coal | 10100203 | 8a | 2886 | 5418.6 | 81.9% | 981.2 | 4437.33 | 16.9076 | 3.06 | 13.85 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | CYCLONE FURNACE | |
95 | 197809AAO | 60970.8 | Midwest Generation LLC | 4911 | 0031 | Joliet 29: Unit 7 Boilers 71 and 72 | 01 | Coal | 10100202 | 8a | 4558 | 1760.7 | 25.0% | 1320.5 | 440.16 | 6.0416 | 4.53 | 1.51 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
96 | 197809AAO | 60970.8 | Midwest Generation LLC | 4911 | 0033 | Joliet 29: Unit 8 Boilers 81 and 82 | 01 | Coal | 10100202 | 8a | 3193 | 1879.2 | 26.2% | 1386.3 | 492.89 | 5.9909 | 4.42 | 1.57 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
97 | 197810AAK | 18014.4 | Will County Electric Generating Station | 4911 | 0010 | UNIT #1 BOILER CYCLONE | 02 | COAL FIRING | 10100223 | 8a | 1728 | 2679.0 | 85.1% | 397.9 | 2281.09 | 9.5894 | 1.42 | 8.17 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | CYCLONE FURNACE | |
98 | 197810AAK | 18014.4 | Will County Electric Generating Station | 4911 | 0012 | UNIT #2 BOILER CYCLONE | 02 | COAL FIRED | 10100223 | 8a | 1712 | 2531.0 | 83.1% | 426.6 | 2104.41 | 9.1506 | 1.54 | 7.61 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | CYCLONE FURNACE | |
99 | 197810AAK | 18014.4 | Will County Electric Generating Station | 4911 | 0014 | UNIT #3 BOILER PULV. DRY BOTTOM - TANGENTIALY FIRE | 02 | COAL FIRED | 10100222 | 8a | 2709 | 873.1 | 23.1% | 671.6 | 201.48 | 2.7744 | 2.13 | 0.64 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
100 | 197810AAK | 18014.4 | Will County Electric Generating Station | 4911 | 0016 | UNIT #4 BOILER PULV. DRY BOTTOM - TANGENTIALY FIRE | 02 | COAL FIRED | 10100222 | 8a | 5016 | 1690.8 | 35.7% | 1086.9 | 603.86 | 6.0994 | 3.92 | 2.18 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
101 | EGU Coal-fired Boilers, Total | 37802 | 24827.2 | 57.3% | 10612.9 | 14214.3 | 82.22 | 34.59 | 47.63 | ||||||||||||||
102 | All Sources in Chicago NAA, Total | Total | Total | 32331 | 55.6% | 14343 | 17988 | 105.9 | 46.2 | 59.7 |
A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Table G-1: NOx Reductions from the Application of NOx RACT in Metro-East NAA | ||||||||||||||||||||||
2 | Mydocument/TSD/NOx RACT-Attachments.xls | ||||||||||||||||||||||
3 | |||||||||||||||||||||||
4 | |||||||||||||||||||||||
5 | Facility ID | Source PTE TPY NOx | Facility Name | SIC | Emission Unit ID | Emission Point Description | Mode ID | Mode Description | SCC # | Emission Unit category | Heat Input Capacity mmbtu/hr | 2005 NOx Emissions tpy | Estimated NOx RACT Reduction , % | Estimated Controlled NOx tpy | Estimated Nox Reduction Tons | Unit Typical Ozone Season NOx tons/day | Estimated Ozone Season Controlled NOx, TPD | Estimated Ozone season NOx Reduction, TPD | Fuel | descr1 | descr3 | descr4 | |
6 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0080 | UTILITY BOILER #15 (BLR-15) | 02 | RFG | 10200701 | 1a1 | 360 | 106.9 | 69.2% | 32.9 | 74.02 | 0.2929 | 0.09 | 0.20 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
7 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0081 | UTILITY BOILER #16 (BLR-16) | 02 | RFG | 10200701 | 1a1 | 249 | 149.4 | 69.2% | 46.0 | 103.43 | 0.4093 | 0.13 | 0.28 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
8 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0082 | UTILITY BOILER #17 (BLR-17) | 02 | RFG | 10200701 | 1a1 | 700 | 125.2 | 69.2% | 38.5 | 86.69 | 0.3431 | 0.11 | 0.24 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
9 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0083 | UTILITY BOILER #18 (BLR-18) | 01 | NATURAL GAS | 10200601 | 1a1 | 249 | 86.8 | 69.2% | 26.7 | 60.10 | 0.2378 | 0.07 | 0.16 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
10 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0083 | UTILITY BOILER #18 (BLR-18) | 02 | REFINERY FUEL GAS | 10200701 | 1a1 | 249 | 30.0 | 69.2% | 9.2 | 20.74 | 0.0821 | 0.03 | 0.06 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
11 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0044 | BOILER HOUSE 2: BOILER #11 - BLAST FURNACE DEPT | 04 | NATURAL GAS FIRING | 10200601 | 1a1 | 225 | 25.7 | 69.2% | 7.9 | 17.78 | 0.0654 | 0.02 | 0.05 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
12 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0044 | BOILER HOUSE 2: BOILER #11 - BLAST FURNACE DEPT | 01 | BLAST FURNACE GAS FIRING | 10200704 | 1a1 | 225 | 31.7 | 69.2% | 9.8 | 21.96 | 0.0454 | 0.01 | 0.03 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | BLAST FURNACE GAS | |
13 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0048 | BOILER HOUSE 2: BOILER #12 - BLAST FURNACE DEPT | 04 | NATURAL GAS FIRING | 10200601 | 1a1 | 225 | 24.8 | 69.2% | 7.6 | 17.15 | 0.0456 | 0.01 | 0.03 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
14 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0048 | BOILER HOUSE 2: BOILER #12 - BLAST FURNACE DEPT | 01 | BLAST FURNACE GAS FIRING | 10200704 | 1a1 | 225 | 21.2 | 69.2% | 6.5 | 14.70 | 0.0436 | 0.01 | 0.03 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | BLAST FURNACE GAS | |
15 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0048 | BOILER HOUSE 2: BOILER #12 - BLAST FURNACE DEPT | 02 | COKE OVEN GAS FIRING | 10200707 | 1a1 | 225 | 64.5 | 69.2% | 19.9 | 44.67 | 0.138 | 0.04 | 0.10 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | COKE OVEN GAS | |
16 | 163045ADT | 168.3 | Elementis Pigments Inc | 2816 | 0061 | Erie City boiler | 01 | Natural gas | 10200601 | 1a1 | 135 | 41.4 | 69.2% | 12.7 | 28.65 | 0.258 | 0.08 | 0.18 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
17 | 163121AAY | 250.1 | Environmental Management Corp | 4961 | 0001 | BOILERS #1, #2 AND #3 | 01 | NATURAL GAS | 10200601 | 1a1 | 393 | 22.4 | 69.2% | 6.9 | 15.53 | 0.0553 | 0.02 | 0.04 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
18 | Gaseous Fuel-fired Boilers >100 mmBtu/hr, Total | 3460.0 | 730.1 | 69.2% | 224.6 | 505.4 | 2.02 | 0.62 | 1.40 | ||||||||||||||
19 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0614 | BOILER NO. 5 | 01 | NATURAL GAS COMBUSTION | 10200602 | 1a2 | 66 | 15.3 | 15.0% | 13.0 | 2.29 | 0.0419 | 0.04 | 0.01 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
20 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0041 | BOILER HOUSE 1: BOILERS 1 TO 7 | 01 | BLAST FURNACE GAS FIRING | 10200704 | 1a2 | 60 | 66.0 | 15.0% | 56.1 | 9.89 | 0.1502 | 0.13 | 0.02 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | BLAST FURNACE GAS | |
21 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0041 | BOILER HOUSE 1: BOILERS 1 TO 7 | 04 | NATURAL GAS FIRING | 10200601 | 1a2 | 420 | 44.6 | 15.0% | 37.9 | 6.69 | 0.1538 | 0.13 | 0.02 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
22 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0041 | BOILER HOUSE 1: BOILERS 1 TO 7 | 02 | COKE OVEN GAS FIRING | 10200707 | 1a2 | 559 | 134.2 | 15.0% | 114.0 | 20.12 | 0.4103 | 0.35 | 0.06 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | COKE OVEN GAS | |
23 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0042 | BOILER HOUSE 1: BOILERS 8 TO 10 | 04 | NATURAL GAS FIRING | 10200602 | 1a2 | 60 | 19.1 | 15.0% | 16.3 | 2.87 | 0.0659 | 0.06 | 0.01 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
24 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0042 | BOILER HOUSE 1: BOILERS 8 TO 10 | 01 | BLAST FURNACE GAS FIRING | 10200704 | 1a2 | 80 | 28.3 | 15.0% | 24.0 | 4.24 | 0.0644 | 0.05 | 0.01 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | BLAST FURNACE GAS | |
25 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0042 | BOILER HOUSE 1: BOILERS 8 TO 10 | 02 | COKE OVEN GAS FIRING | 10200707 | 1a2 | 60 | 57.5 | 15.0% | 48.9 | 8.63 | 0.1758 | 0.15 | 0.03 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | COKE OVEN GAS | |
26 | Gaseous Fuel-fired Boilers <=100 mmBtu/hr, Total | 1305 | 364.9 | 15.0% | 310.2 | 54.7 | 1.06 | 0.90 | 0.16 | ||||||||||||||
27 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0004 | CAT REFORMER #1: FEED PREHEATER (HTR-CR1-H1) | 02 | RFG | 30600106 | 2a1 | 165 | 130.8 | 28.6% | 93.5 | 37.38 | 0.3584 | 0.26 | 0.10 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
28 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0005 | CAT REFORMER #1: FIRST INTERREACTOR HEATER (HTR-CR | 02 | RFG | 30600104 | 2a1 | 162 | 164.3 | 28.6% | 117.4 | 46.95 | 0.4502 | 0.32 | 0.13 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
29 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0014 | HYDROCRACKING UNIT: FRACTIONATOR REBOILER (HTR-HCU | 02 | RFG | 30600106 | 2a1 | 235 | 152.0 | 28.6% | 108.6 | 43.43 | 0.4164 | 0.30 | 0.12 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
30 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0018 | BENZENE EXTRACTION UNIT #2 (HTR-BEU-HM2) | 02 | RFG | 30600106 | 2a1 | 110 | 59.5 | 28.6% | 42.5 | 16.99 | 0.163 | 0.12 | 0.05 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
31 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0024 | DISTILLING UNIT: HTR-DU1-F301 | 02 | REFINERY GAS (RFG) | 30600106 | 2a1 | 120 | 138.8 | 28.6% | 99.1 | 39.66 | 0.3803 | 0.27 | 0.11 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
32 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0025 | DISTILLING UNIT: HTR-DU1-F302 | 01 | RFG | 30600106 | 2a1 | 200 | 226.9 | 28.6% | 162.1 | 64.84 | 0.6217 | 0.44 | 0.18 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
33 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0029 | DISTILLING UNIT: WEST CRUDE HEATER (HTR-DU2-F202) | 02 | REFINERY GAS (RFG) | 30600104 | 2a1 | 230 | 221.7 | 28.6% | 158.3 | 63.33 | 0.6073 | 0.43 | 0.17 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
34 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0030 | DISTILLING UNIT: EAST CRUDE HEATER (HTR-DU2-F203) | 01 | RFG | 30600106 | 2a1 | 230 | 226.6 | 28.6% | 161.8 | 64.74 | 0.6208 | 0.44 | 0.18 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
35 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0073 | ALKYLATION UNIT: HTR-ALKY-HM2 | 02 | RFG | 30600106 | 2a1 | 110 | 76.6 | 28.6% | 54.7 | 21.89 | 0.2099 | 0.15 | 0.06 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
36 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0084 | CAT REFORMER #2: CHARGE REHEATER (HTR-CR2-N) | 01 | RFG | 30600106 | 2a1 | 137.5 | 65.4 | 28.6% | 46.7 | 18.68 | 0.1792 | 0.13 | 0.05 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
37 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0086 | HEATER CR2-S (RFG FIRING) | 01 | FUEL COMBUSTION EMISSIONS RFG | 30600104 | 2a1 | 137.5 | 65.4 | 28.6% | 46.7 | 18.68 | 0.1792 | 0.13 | 0.05 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
38 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0091 | CAT REFORMER #3: CHARGE HEATER (HTR-CR3-H4) | 01 | RFG | 30600106 | 2a1 | 144.7 | 165.1 | 28.6% | 118.0 | 47.18 | 0.4524 | 0.32 | 0.13 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
39 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0092 | CAT REFORMER #3: FIRST INTERREACTOR HEATER (HTR-CR | 02 | RFG | 30600106 | 2a1 | 141 | 136.8 | 28.6% | 97.7 | 39.08 | 0.3748 | 0.27 | 0.11 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
40 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0094 | KEROSENE HYDROTREATER: KHT HEATER (HTR-KHT) | 01 | RFG | 30600106 | 2a1 | 109 | 106.2 | 28.6% | 75.8 | 30.33 | 0.2909 | 0.21 | 0.08 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
41 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0617 | DELAYED COKER UNIT HEATER H-20 | 02 | REFINERY FUEL GAS | 30600106 | 2a1 | 231 | 98.1 | 28.6% | 70.1 | 28.03 | 0.2688 | 0.19 | 0.08 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
42 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0623 | NO.2 CRUDE UNIT HEATER H-24 | 01 | NATURAL GAS COMBUSTION | 30600104 | 2a1 | 314 | 150.2 | 28.6% | 107.3 | 42.92 | 1.0018 | 0.72 | 0.29 | NATURAL GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
43 | Process Htrs Gas fired >100 mmBtu/hr, Total | 2776.7 | 2184.4 | 28.6% | 1560.3 | 624.1 | 6.58 | 4.70 | 1.88 | ||||||||||||||
44 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0006 | CAT REFORMER #1: SECOND INTERREACTOR HEATER (HTR-C | 02 | RFG | 30600104 | 2a2 | 78 | 27.8 | 15.0% | 23.6 | 4.17 | 0.0761 | 0.06 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
45 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0007 | CAT REFORMER #1: STABILIZER REBOILER (HTR-CR1-H4) | 02 | RFG | 30600106 | 2a2 | 100 | 16.7 | 15.0% | 14.2 | 2.51 | 0.0458 | 0.04 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
46 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0009 | CAT REFORMER #1: THIRD INTERREACTOR HEATER (HTR-CR | 02 | RFG | 30600106 | 2a2 | 100 | 86.7 | 15.0% | 73.7 | 13.00 | 0.2375 | 0.20 | 0.04 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
47 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0017 | BENZENE EXTRACTION UNIT #1 (HTR-BEU-HM1) | 02 | RFG | 30600106 | 2a2 | 100 | 81.7 | 15.0% | 69.5 | 12.26 | 0.2239 | 0.19 | 0.03 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
48 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0031 | VACUUM FLASHER UNITS #1-3 (VF-1, -2, -3) | 01 | 30600104 | 2a2 | 273 | 140.2 | 15.0% | 119.1 | 21.02 | 0.384 | 0.33 | 0.06 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | ||
49 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0033 | RECTIFIED ABSORPTION UNIT: REBOILER HEATER (HTR-RA | 01 | RFG | 30600106 | 2a2 | 69 | 23.0 | 15.0% | 19.5 | 3.44 | 0.0629 | 0.05 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
50 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0036 | CRACKED ABSORPTION UNIT (HTR-CAU-ROSTILL) | 02 | RFG AND RFP | 30600106 | 2a2 | 95 | 30.0 | 15.0% | 25.5 | 4.50 | 0.0822 | 0.07 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED |
51 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0042 | CO HEATER (HTRR-CCU1-CO) | 01 | RFG | 30600104 | 2a2 | 17 | 91.9 | 15.0% | 78.1 | 13.78 | 0.2518 | 0.21 | 0.04 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
52 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0056 | CO HEATER (HTRR-CCU2-CO) | 01 | RFG | 30600104 | 2a2 | 80 | 82.1 | 15.0% | 69.8 | 12.31 | 0.2249 | 0.19 | 0.03 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
53 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0085 | HYDRODESULFURIZATION UNIT #1: CHARGE HEATER (HTR-H | 01 | RFG | 30600106 | 2a2 | 67.3 | 19.6 | 15.0% | 16.6 | 2.94 | 0.0536 | 0.05 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
54 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0088 | HYDRODESULFURIZATION UNIT #2: CHARGE HEATER (HTR-H | 01 | RFG | 30600106 | 2a2 | 81 | 26.2 | 15.0% | 22.3 | 3.94 | 0.0719 | 0.06 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
55 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0093 | CAT REFORMER #3: SECOND INTERREACTOR HEATER (HTR-C | 02 | RFG | 30600106 | 2a2 | 74 | 27.1 | 15.0% | 23.0 | 4.06 | 0.0742 | 0.06 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
56 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0154 | VACUUM FLASHER #2: EAST HEATER (HTR-VF2-F205) | 01 | RFG | 30600106 | 2a2 | 61 | 15.9 | 15.0% | 13.5 | 2.38 | 0.0436 | 0.04 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
57 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0155 | VACUUM FLASHER #1: NORTH HEATER (HTR-VF-1-NORTH) | 01 | 30600105 | 2a2 | 100 | 45.5 | 15.0% | 38.7 | 6.83 | 0.1247 | 0.11 | 0.02 | NATURAL GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | NATURAL GAS-FIRED | ||
58 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0156 | VACUUM FLASHER #1: SOUTH HEATER (HTR-VF-1-SOUTH) | 01 | 30600105 | 2a2 | 100 | 50.9 | 15.0% | 43.3 | 7.63 | 0.1394 | 0.12 | 0.02 | NATURAL GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | NATURAL GAS-FIRED | ||
59 | Process Htrs Gas fired <100 mmBtu/hr, Total | 1395.3 | 765.2 | 15.0% | 650.4 | 114.8 | 2.10 | 1.78 | 0.31 | ||||||||||||||
60 | 119010AAE | 1916.7 | Alton Steel Inc | 3312 | 0033 | 14 INCH BILLET REHEAT FURNACE | 01 | GAS FIRED | 30300933 | 7a | 255 | 47.6 | 77.0% | 11.0 | 36.68 | 0.3174 | 0.07 | 0.24 | NATURAL GAS | PRIMARY METAL PRODUCTION | STEEL PRODUCTION | REHEAT FURNACES | |
61 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0015 | SLAB FURNACE #1 | 02 | COKE OVEN GAS FIRING | 39000689 | 7a | 321.8 | 84.9 | 77.0% | 19.5 | 65.40 | 0.4144 | 0.10 | 0.32 | PROCESS GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
62 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0015 | SLAB FURNACE #1 | 01 | NATURAL GAS FIRING | 39000689 | 7a | 321.8 | 266.2 | 77.0% | 61.2 | 205.00 | 0.7086 | 0.16 | 0.55 | NATURAL GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
63 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0018 | SLAB FURNACE #4 | 01 | NATURAL GAS FIRING | 39000689 | 7a | 495 | 113.8 | 77.0% | 26.2 | 87.65 | 0.9587 | 0.22 | 0.74 | NATURAL GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
64 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0122 | SLAB FURNACE #2 | 02 | COKE OVEN GAS FIRING | 39000689 | 7a | 322 | 82.2 | 77.0% | 18.9 | 63.32 | 0.3938 | 0.09 | 0.30 | PROCESS GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
65 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0122 | SLAB FURNACE #2 | 01 | NATURAL GAS FIRING | 39000689 | 7a | 322 | 149.2 | 77.0% | 34.3 | 114.89 | 0.6908 | 0.16 | 0.53 | NATURAL GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
66 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0123 | SLAB FURNACE #3 | 02 | COKE OVEN GAS FIRING | 39000689 | 7a | 322 | 101.6 | 77.0% | 23.4 | 78.19 | 0.4321 | 0.10 | 0.33 | PROCESS GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
67 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0123 | SLAB FURNACE #3 | 01 | NATURAL GAS FIRING | 39000689 | 7a | 322 | 162.8 | 77.0% | 37.5 | 125.39 | 0.7052 | 0.16 | 0.54 | NATURAL GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
68 | Reheat Furnaces, Iron and Steel, Total | 2681.6 | 1008.5 | 77.0% | 231.9 | 776.5 | 4.62 | 1.06 | 3.56 | ||||||||||||||
69 | 119020AAE | 24289.8 | Dynegy Midwest Generation Inc | 4911 | 0001 | BOILER 5 PULV DRY TANGENTIAL | 01 | COAL FIRING | 10100202 | 8a | 3920 | 1910.9 | 43.4% | 1081.6 | 829.26 | 5.3293 | 3.02 | 2.31 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
70 | 119020AAE | 24289.8 | Dynegy Midwest Generation Inc | 4911 | 0003 | BLR 4 PULV DRY BTM TANGENTIAL | 01 | COAL FIRING | 10100202 | 8a | 1030 | 456.6 | 32.8% | 306.7 | 149.93 | 1.5082 | 1.01 | 0.50 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
71 | 157851AAA | 4875.6 | Dynegy Midwest Generation Inc | 4911 | 0001 | BOILER #1 | 01 | COAL FIRING | 10100202 | 8a | 5890 | 1106.9 | -20.0% | 1328.3 | -221.39 | 3.627 | 4.35 | -0.73 | COAL - SUBBITUMINOUS | ||||
72 | 157851AAA | 4875.6 | Dynegy Midwest Generation Inc | 4911 | 0002 | BOILER #2 | 01 | COAL FIRING | 10100202 | 8a | 5900 | 1495.3 | -22.2% | 1827.6 | -332.29 | 3.547 | 4.34 | -0.79 | COAL - SUBBITUMINOUS | ||||
73 | 157851AAA | 4875.6 | Dynegy Midwest Generation Inc | 4911 | 0013 | BOILER #3 | 01 | COAL FIRING | 10100202 | 8a | 5800 | 2271.6 | 7.8% | 2095.0 | 176.68 | 6.624 | 6.11 | 0.52 | COAL - SUBBITUMINOUS | ||||
74 | EGU Coal-fired Boilers, Total | 22540 | 7241 | 8.3% | 6639 | 602 | 20.6 | 18.8 | 1.8 | ||||||||||||||
75 | All Sources in Metro-East NAA, Total | 12294 | 21.8% | 9617 | 2678 | 37 | 28 | 9 |
A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Table H-1: NOx Reductions from the Application of NOx RACT in Chicago and Metro-East NAA | ||||||||||||||||||||||
2 | Mydocument/TSD/NOx RACT-Attachments.xls | ||||||||||||||||||||||
3 | |||||||||||||||||||||||
4 | Sr. No. | Facility ID | Source PTE TPY NOx | Facility Name | SIC | Emission Unit ID | Emission Point Description | Mode ID | SCC # | Emission Unit category | Heat Input Capacity mmbtu/hr | 2005 NOx Emissions tpy | Estimated NOx RACT Reduction , % | Estimated Controlled NOx tpy | Estimated Nox Reduction Tons | Unit Typical Ozone Season NOx tons/day | Estimated Ozone Season Controlled NOx, TPD | Estimated Ozone season NOx Reduction, TPD | Fuel | descr1 | descr3 | descr4 | |
5 | 1 | 031003ADA | 516.7 | Alsip Paper Condominium Assn | 4931 | 0004 | BOILERS #1 AND #2 | 01 | 10200601 | 1a1 | 310 | 173.1 | 69.2% | 53.3 | 119.85 | 0.2184 | 0.07 | 0.151 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
6 | 2 | 031012AAO | 139.6 | Nalco Co | 2899 | 0049 | BOILER #1 | 01 | 10200601 | 1a1 | 114.6 | 17.9 | 69.2% | 5.5 | 12.41 | 0.0656 | 0.02 | 0.05 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
7 | 3 | 031012AAO | 139.6 | Nalco Co | 2899 | 0061 | BOILER #2 | 01 | 10200601 | 1a1 | 124 | 42.3 | 69.2% | 13.0 | 29.26 | 0.2875 | 0.09 | 0.20 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
8 | 4 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0046 | UTILITIES - BOILER #5 (A-23-93) | 01 | 10200601 | 1a1 | 312.5 | 39.2 | 69.2% | 12.0 | 27.11 | 0.064 | 0.02 | 0.04 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
9 | 5 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0160 | UTILITIES - BOILER #6 (A23-144) | 01 | 10200601 | 1a1 | 600 | 16.8 | 69.2% | 5.2 | 11.66 | 0.0384 | 0.01 | 0.03 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
10 | 6 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0233 | UTILITIES - BOILER #7 | 01 | 10200601 | 1a1 | 240 | 30.5 | 69.2% | 9.4 | 21.09 | 0.087 | 0.03 | 0.06 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
11 | 7 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0041 | UTILITIES - BOILER #1 (A-23-92) | 01 | 10200202 | 1e2 | 332.5 | 760.7 | 73.9% | 198.4 | 562.26 | 3.1979 | 0.83 | 2.36 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
12 | 8 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0042 | UTILITIES - BOILER #2 (A-23-92) | 01 | 10200202 | 1e2 | 332.5 | 796.9 | 73.9% | 207.9 | 588.98 | 3.2401 | 0.85 | 2.39 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
13 | 9 | 031012ABI | 4542.4 | Corn Products International Inc | 2046 | 0045 | UTILITIES - BOILER #3 (A-23-93) | 01 | 10200202 | 1e2 | 332.5 | 772.6 | 73.9% | 201.6 | 571.08 | 2.4953 | 0.65 | 1.84 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
14 | 10 | 031045AAJ | 316.1 | Kimble Glass Inc | 0006 | GLASS MELTING FURNACE B | 01 | 30501402 | 3 | 25 | 50.8 | 50.0% | 25.4 | 25.38 | 0.14 | 0.07 | 0.07 | ||||||
15 | 11 | 031069AAI | 1113.0 | Saint-Gobain Containers Inc | 0013 | 3 GLASS MELTING FURNACES (1, 2 AND 3) | 01 | 30501402 | 3 | 120 | 681.2 | 50.0% | 340.6 | 340.57 | 1.87584 | 0.94 | 0.94 | NATURAL GAS | |||||
16 | 12 | 031081AEQ | 286.5 | Northwestern University | 8221 | 0001 | 3 EC Boilers (#1, 2 and 3 - Central Utility Plant) | 01 | 10300601 | 1a1 | 556 | 156.7 | 69.2% | 48.2 | 108.46 | 0.4436 | 0.14 | 0.31 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MMBTU/HR | |
17 | 13 | 031258ABR | 516.7 | Mittal Steel USA - Riverdale Inc | 3312 | 0184 | TUNNEL FURNACE | 01 | 30390003 | 7b | 123 | 44.1 | 60.0% | 17.6 | 26.47 | 0.1502 | 0.06 | 0.09 | NATURAL GAS | PRIMARY METAL PRODUCTION | PROCESS HEATERS | NATURAL GAS | |
18 | 14 | 031600ADY | 1338.7 | Carmeuse Lime Inc | 3274 | 0024 | ROTARY KILN 4 | 01 | 30501605 | 5a | 155.6 | 250.4 | 30.0% | 175.2 | 75.11 | 0.9868 | 0.69 | 0.30 | PROPANE | MINERAL PRODUCTS | LIME MANUFACTURE | CALCIMATIC KILN | |
19 | 15 | 031600ADY | 1338.7 | Carmeuse Lime Inc | 3274 | 0028 | ROTARY KILN 5 | 01 | 30501604 | 5a | 433.3 | 484.1 | 30.0% | 338.8 | 145.22 | 1.554 | 1.09 | 0.47 | PROPANE | MINERAL PRODUCTS | LIME MANUFACTURE | CALCINING: ROTARY KILN | |
20 | 16 | 031600AIN | 32962.1 | Crawford Electric Generating Station | 4911 | 0013 | Unit 7 | 01 | 10100226 | 8a | 2342 | 873.9 | 32.3% | 591.3 | 282.53 | 2.746 | 1.86 | 0.89 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
21 | 17 | 031600AIN | 32962.1 | Crawford Electric Generating Station | 4911 | 0016 | Unit 8 | 01 | 10100226 | 8a | 3556 | 1375.0 | 39.6% | 830.5 | 544.46 | 4.1789 | 2.52 | 1.65 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
22 | 18 | 031600AMI | 13414.4 | Fisk Electric Generating Station | 4911 | 0010 | FISK UNIT #19 | 01 | 10100226 | 8a | 2896 | 1125.6 | 34.8% | 734.1 | 391.52 | 3.8275 | 2.50 | 1.33 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
23 | 19 | 031600CAO | 221.5 | Kraft Foods Global Inc | 2052 | 0107 | BOILER #5 | 01 | 10200602 | 1a2 | 63.3 | 20.7 | 15.0% | 17.6 | 3.11 | 0.012 | 0.01 | 0.00 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
24 | 20 | 031600DDJ | 175.6 | National Railroad Passenger Corp | 4013 | 0001 | BOILER #1 | 01 | 10200602 | 1a2 | 77.4 | 16.0 | 15.0% | 13.6 | 2.40 | 0 | 0.00 | 0.00 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
25 | 21 | 031600FLT | 204.3 | University of Chicago | 8221 | 0001 | BOILERS 1-4 | 01 | 10200601 | 1a1 | 782 | 63.5 | 69.2% | 19.5 | 43.94 | 0.1142 | 0.04 | 0.08 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
26 | 22 | 031600FMX | 114.3 | Northwestern Memorial Hospital | 8062 | 0002 | 5 Boilers | 01 | 10300602 | 1a2 | 126 | 31.8 | 15.0% | 27.0 | 4.77 | 0.0874 | 0.07 | 0.01 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
27 | 23 | 031600FQP | 202.5 | Chicago - Dept of Aviation | 4581 | 0003 | 8 HIGH TEMPERATURE WATER GENERATORS (HTWG-4001 - 4 | 01 | 10200602 | 1a2 | 758.6 | 26.0 | 15.0% | 22.1 | 3.89 | 0.3708 | 0.32 | 0.06 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
28 | 24 | 031817AAB | 108.9 | Loyola University Medical Center | 8221 | 0017 | BOILERS 2, 3 AND 4 | 01 | 10300602 | 1a2 | 154.9 | 20.6 | 15.0% | 17.5 | 3.09 | 0.0481 | 0.04 | 0.01 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
29 | 25 | 031817AAL | 292.7 | VA Edward Hines Jr Hospital | 8062 | 0004 | BOILERS 1-4 | 01 | 10300602 | 1a1 | 200 | 17.8 | 69.2% | 5.5 | 12.35 | 0.0231 | 0.01 | 0.02 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
30 | 26 | 043802AAA | 727.9 | Argonne National Laboratory | 8733 | 0001 | Boiler #1 | 01 | 10300601 | 1a1 | 106 | 25.2 | 69.2% | 7.8 | 17.47 | 0.082 | 0.03 | 0.06 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MMBTU/HR | |
31 | 27 | 043802AAA | 727.9 | Argonne National Laboratory | 8733 | 0003 | Boiler #3 | 01 | 10300601 | 1a1 | 106 | 19.4 | 69.2% | 6.0 | 13.42 | 0 | 0.00 | 0.00 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MMBTU/HR | |
32 | 28 | 043802AAA | 727.9 | Argonne National Laboratory | 8733 | 0004 | Boiler #4 | 01 | 10300601 | 1a1 | 106 | 19.0 | 69.2% | 5.8 | 13.15 | 0 | 0.00 | 0.00 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MMBTU/HR | |
33 | 29 | 043802AAA | 727.9 | Argonne National Laboratory | 8733 | 0005 | Boiler #5 | 04 | 10300205 | 1e3 | 212 | 21.6 | 63.8% | 7.8 | 13.8 | 0 | 0.00 | 0.00 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: WET BOTTOM | |
34 | 30 | 063800AAC | 628.1 | Equistar Chemicals LP | 2869 | 0025 | ETHYLENE PLANT - STEAM SUPERHEATER | 01 | 10200799 | 1a1 | 141 | 47.2 | 69.2% | 14.5 | 32.69 | 0.1294 | 0.04 | 0.09 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | > 100 MBTU/HR | |
35 | 31 | 063800AAC | 628.1 | Equistar Chemicals LP | 2869 | 0026 | ETHYLENE PLANT - 14 CRACKING FURNACES (101-114) | 01 | 30600104 | 2a1 | 1277 | 357.3 | 28.6% | 255.2 | 102.07 | 0.9788 | 0.70 | 0.28 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
36 | 32 | 063800AAE | 491.0 | Akzo Nobel Surface Chemistry LLC | 2869 | 0033 | STEAM BOILER J-090 (NEBRASKA) | 03 | 10201201 | 1e4 | 40.2 | 37.1 | 15.0% | 31.6 | 5.57 | 0.2271 | 0.19 | 0.03 | OTHER | EXTERNAL COMBUSTION BOILERS | SOLID WASTE | SPECIFY WASTE MATERIAL IN COMMENTS | |
37 | 33 | 063800AAE | 491.0 | Akzo Nobel Surface Chemistry LLC | 2869 | 0017 | DOWTHERM BOILER | 02 | 10201201 | 2c3 | 17 | 26.5 | 15.0% | 22.5 | 3.97 | 0.103 | 0.09 | 0.02 | OTHER | EXTERNAL COMBUSTION BOILERS | SOLID WASTE | SPECIFY WASTE MATERIAL IN COMMENTS | |
38 | 34 | 063800AAM | 243.8 | Aux Sable Liquid Products | 1321 | 0019 | Heaters 1H101, 2H101, H301, H601, H602, 501A, 501B | 01 | 39000699 | 2a1 | 859.3 | 156.1 | 28.6% | 111.5 | 44.59 | 0.4359 | 0.31 | 0.12 | NATURAL GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
39 | 35 | 089800AAH | 711.8 | Dial Corp | 2841 | 0075 | BOILERS #1 AND #2 | 01 | 10200601 | 1a1 | 210 | 124.1 | 69.2% | 38.2 | 85.89 | 0.3475 | 0.11 | 0.24 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
40 | 36 | 097125AAA | 582.3 | Abbott Laboratories | 2834 | 0858 | BOILER #10 NC (CED) | 01 | 10200601 | 1a1 | 220 | 24.7 | 69.2% | 7.6 | 17.10 | 0.0761 | 0.02 | 0.05 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
41 | 37 | 097125AAA | 582.3 | Abbott Laboratories | 2834 | 0070 | BOILER #5NC (TT-16) (CED) | 01 | 10100204 | 1e4 | 85 | 85.5 | 15.0% | 72.7 | 12.83 | 0.2898 | 0.25 | 0.04 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | SPREADER STOKER | |
42 | 38 | 097125AAA | 582.3 | Abbott Laboratories | 2834 | 0242 | BOILER #6 NC (TT-20) (CED) | 01 | 10100204 | 1e4 | 85 | 77.1 | 15.0% | 65.5 | 11.56 | 0.2743 | 0.23 | 0.04 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | SPREADER STOKER | |
43 | 39 | 097190AAC | 47103.0 | Waukegan Electric Generating Station | 4911 | 0031 | UNIT #6 BOILER | 01 | 10100203 | 8a | 1024 | 1627.3 | 86.6% | 218.6 | 1408.72 | 5.9705 | 0.80 | 5.17 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | CYCLONE FURNACE | |
44 | 40 | 097190AAC | 47103.0 | Waukegan Electric Generating Station | 4911 | 0033 | UNIT #8 BOILER | 01 | 10100226 | 8a | 3271 | 1595.4 | 33.8% | 1055.8 | 539.62 | 4.6723 | 3.09 | 1.58 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
45 | 41 | 097190AAC | 47103.0 | Waukegan Electric Generating Station | 4911 | 0036 | UNIT #7 BOILER | 01 | 10100226 | 8a | 2911 | 1397.9 | 34.8% | 911.6 | 486.21 | 4.2667 | 2.78 | 1.48 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM (TANGENTIAL) | |
46 | 42 | 097809AAD | 1629.2 | Abbott Laboratories | 2834 | 0006 | Boiler 4AP | 01 | 10200204 | 1e4 | 83 | 147.8 | 15.0% | 125.6 | 22.17 | 0.4492 | 0.38 | 0.07 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | SPREADER STOKER | |
47 | 43 | 097809AAD | 1629.2 | Abbott Laboratories | 2834 | 0103 | Boiler #5AP | 01 | 10200204 | 1e4 | 83 | 129.2 | 15.0% | 109.8 | 19.38 | 0.3739 | 0.32 | 0.06 | COAL - BITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | SPREADER STOKER | |
48 | 44 | 097811AAC | 826.8 | Naval Training Center | 9711 | 0011 | BUILDING 11: BOILERS #5 AND #6 | 01 | 10200601 | 1a1 | 680 | 94.0 | 69.2% | 28.9 | 65.06 | 0.0341 | 0.01 | 0.02 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
49 | 45 | 119010AAE | 1916.7 | Alton Steel Inc | 3312 | 0033 | 14 INCH BILLET REHEAT FURNACE | 01 | 30300933 | 7a | 255 | 47.6 | 77.0% | 11.0 | 36.68 | 0.3174 | 0.07 | 0.24 | NATURAL GAS | PRIMARY METAL PRODUCTION | STEEL PRODUCTION | REHEAT FURNACES | |
50 | 46 | 119020AAE | 24289.8 | Dynegy Midwest Generation Inc | 4911 | 0001 | BOILER 5 PULV DRY TANGENTIAL | 01 | 10100202 | 8a | 3920 | 1910.9 | 43.4% | 1081.6 | 829.26 | 5.3293 | 3.02 | 2.31 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM |
51 | 47 | 119020AAE | 24289.8 | Dynegy Midwest Generation Inc | 4911 | 0003 | BLR 4 PULV DRY BTM TANGENTIAL | 01 | 10100202 | 8a | 1030 | 456.6 | 32.8% | 306.7 | 149.93 | 1.5082 | 1.01 | 0.50 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
52 | 48 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0080 | UTILITY BOILER #15 (BLR-15) | 02 | 10200701 | 1a1 | 360 | 106.9 | 69.2% | 32.9 | 74.02 | 0.2929 | 0.09 | 0.20 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
53 | 49 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0081 | UTILITY BOILER #16 (BLR-16) | 02 | 10200701 | 1a1 | 249 | 149.4 | 69.2% | 46.0 | 103.43 | 0.4093 | 0.13 | 0.28 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
54 | 50 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0082 | UTILITY BOILER #17 (BLR-17) | 02 | 10200701 | 1a1 | 700 | 125.2 | 69.2% | 38.5 | 86.69 | 0.3431 | 0.11 | 0.24 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
55 | 51 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0083 | UTILITY BOILER #18 (BLR-18) | 01 | 10200601 | 1a1 | 249 | 86.8 | 69.2% | 26.7 | 60.10 | 0.2378 | 0.07 | 0.16 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
56 | 52 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0083 | UTILITY BOILER #18 (BLR-18) | 02 | 10200701 | 1a1 | 249 | 30.0 | 69.2% | 9.2 | 20.74 | 0.0821 | 0.03 | 0.06 | OTHER GASEOUS FUEL | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
57 | 53 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0614 | BOILER NO. 5 | 01 | 10200602 | 1a2 | 66 | 15.3 | 15.0% | 13.0 | 2.29 | 0.0419 | 0.04 | 0.01 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
58 | 54 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0004 | CAT REFORMER #1: FEED PREHEATER (HTR-CR1-H1) | 02 | 30600106 | 2a1 | 165 | 130.8 | 28.6% | 93.5 | 37.38 | 0.3584 | 0.26 | 0.10 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
59 | 55 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0005 | CAT REFORMER #1: FIRST INTERREACTOR HEATER (HTR-CR | 02 | 30600104 | 2a1 | 162 | 164.3 | 28.6% | 117.4 | 46.95 | 0.4502 | 0.32 | 0.13 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
60 | 56 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0014 | HYDROCRACKING UNIT: FRACTIONATOR REBOILER (HTR-HCU | 02 | 30600106 | 2a1 | 235 | 152.0 | 28.6% | 108.6 | 43.43 | 0.4164 | 0.30 | 0.12 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
61 | 57 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0018 | BENZENE EXTRACTION UNIT #2 (HTR-BEU-HM2) | 02 | 30600106 | 2a1 | 110 | 59.5 | 28.6% | 42.5 | 16.99 | 0.163 | 0.12 | 0.05 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
62 | 58 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0024 | DISTILLING UNIT: HTR-DU1-F301 | 02 | 30600106 | 2a1 | 120 | 138.8 | 28.6% | 99.1 | 39.66 | 0.3803 | 0.27 | 0.11 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
63 | 59 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0025 | DISTILLING UNIT: HTR-DU1-F302 | 01 | 30600106 | 2a1 | 200 | 226.9 | 28.6% | 162.1 | 64.84 | 0.6217 | 0.44 | 0.18 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
64 | 60 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0029 | DISTILLING UNIT: WEST CRUDE HEATER (HTR-DU2-F202) | 02 | 30600104 | 2a1 | 230 | 221.7 | 28.6% | 158.3 | 63.33 | 0.6073 | 0.43 | 0.17 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
65 | 61 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0030 | DISTILLING UNIT: EAST CRUDE HEATER (HTR-DU2-F203) | 01 | 30600106 | 2a1 | 230 | 226.6 | 28.6% | 161.8 | 64.74 | 0.6208 | 0.44 | 0.18 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
66 | 62 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0073 | ALKYLATION UNIT: HTR-ALKY-HM2 | 02 | 30600106 | 2a1 | 110 | 76.6 | 28.6% | 54.7 | 21.89 | 0.2099 | 0.15 | 0.06 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
67 | 63 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0084 | CAT REFORMER #2: CHARGE REHEATER (HTR-CR2-N) | 01 | 30600106 | 2a1 | 137.5 | 65.4 | 28.6% | 46.7 | 18.68 | 0.1792 | 0.13 | 0.05 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
68 | 64 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0086 | HEATER CR2-S (RFG FIRING) | 01 | 30600104 | 2a1 | 137.5 | 65.4 | 28.6% | 46.7 | 18.68 | 0.1792 | 0.13 | 0.05 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
69 | 65 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0091 | CAT REFORMER #3: CHARGE HEATER (HTR-CR3-H4) | 01 | 30600106 | 2a1 | 144.7 | 165.1 | 28.6% | 118.0 | 47.18 | 0.4524 | 0.32 | 0.13 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
70 | 66 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0092 | CAT REFORMER #3: FIRST INTERREACTOR HEATER (HTR-CR | 02 | 30600106 | 2a1 | 141 | 136.8 | 28.6% | 97.7 | 39.08 | 0.3748 | 0.27 | 0.11 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
71 | 67 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0094 | KEROSENE HYDROTREATER: KHT HEATER (HTR-KHT) | 01 | 30600106 | 2a1 | 109 | 106.2 | 28.6% | 75.8 | 30.33 | 0.2909 | 0.21 | 0.08 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
72 | 68 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0617 | DELAYED COKER UNIT HEATER H-20 | 02 | 30600106 | 2a1 | 231 | 98.1 | 28.6% | 70.1 | 28.03 | 0.2688 | 0.19 | 0.08 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
73 | 69 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0623 | NO.2 CRUDE UNIT HEATER H-24 | 01 | 30600104 | 2a1 | 314 | 150.2 | 28.6% | 107.3 | 42.92 | 1.0018 | 0.72 | 0.29 | NATURAL GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
74 | 70 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0006 | CAT REFORMER #1: SECOND INTERREACTOR HEATER (HTR-C | 02 | 30600104 | 2a2 | 78 | 27.8 | 15.0% | 23.6 | 4.17 | 0.0761 | 0.06 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
75 | 71 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0007 | CAT REFORMER #1: STABILIZER REBOILER (HTR-CR1-H4) | 02 | 30600106 | 2a2 | 100 | 16.7 | 15.0% | 14.2 | 2.51 | 0.0458 | 0.04 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
76 | 72 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0009 | CAT REFORMER #1: THIRD INTERREACTOR HEATER (HTR-CR | 02 | 30600106 | 2a2 | 100 | 86.7 | 15.0% | 73.7 | 13.00 | 0.2375 | 0.20 | 0.04 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
77 | 73 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0017 | BENZENE EXTRACTION UNIT #1 (HTR-BEU-HM1) | 02 | 30600106 | 2a2 | 100 | 81.7 | 15.0% | 69.5 | 12.26 | 0.2239 | 0.19 | 0.03 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
78 | 74 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0031 | VACUUM FLASHER UNITS #1-3 (VF-1, -2, -3) | 01 | 30600104 | 2a2 | 273 | 140.2 | 15.0% | 119.1 | 21.02 | 0.384 | 0.33 | 0.06 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
79 | 75 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0033 | RECTIFIED ABSORPTION UNIT: REBOILER HEATER (HTR-RA | 01 | 30600106 | 2a2 | 69 | 23.0 | 15.0% | 19.5 | 3.44 | 0.0629 | 0.05 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
80 | 76 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0036 | CRACKED ABSORPTION UNIT (HTR-CAU-ROSTILL) | 02 | 30600106 | 2a2 | 95 | 30.0 | 15.0% | 25.5 | 4.50 | 0.0822 | 0.07 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
81 | 77 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0042 | CO HEATER (HTRR-CCU1-CO) | 01 | 30600104 | 2a2 | 17 | 91.9 | 15.0% | 78.1 | 13.78 | 0.2518 | 0.21 | 0.04 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
82 | 78 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0056 | CO HEATER (HTRR-CCU2-CO) | 01 | 30600104 | 2a2 | 80 | 82.1 | 15.0% | 69.8 | 12.31 | 0.2249 | 0.19 | 0.03 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
83 | 79 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0085 | HYDRODESULFURIZATION UNIT #1: CHARGE HEATER (HTR-H | 01 | 30600106 | 2a2 | 67.3 | 19.6 | 15.0% | 16.6 | 2.94 | 0.0536 | 0.05 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
84 | 80 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0088 | HYDRODESULFURIZATION UNIT #2: CHARGE HEATER (HTR-H | 01 | 30600106 | 2a2 | 81 | 26.2 | 15.0% | 22.3 | 3.94 | 0.0719 | 0.06 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
85 | 81 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0093 | CAT REFORMER #3: SECOND INTERREACTOR HEATER (HTR-C | 02 | 30600106 | 2a2 | 74 | 27.1 | 15.0% | 23.0 | 4.06 | 0.0742 | 0.06 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
86 | 82 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0154 | VACUUM FLASHER #2: EAST HEATER (HTR-VF2-F205) | 01 | 30600106 | 2a2 | 61 | 15.9 | 15.0% | 13.5 | 2.38 | 0.0436 | 0.04 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
87 | 83 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0155 | VACUUM FLASHER #1: NORTH HEATER (HTR-VF-1-NORTH) | 01 | 30600105 | 2a2 | 100 | 45.5 | 15.0% | 38.7 | 6.83 | 0.1247 | 0.11 | 0.02 | NATURAL GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | NATURAL GAS-FIRED | |
88 | 84 | 119090AAA | 13872.0 | ConocoPhillips Co | 2911 | 0156 | VACUUM FLASHER #1: SOUTH HEATER (HTR-VF-1-SOUTH) | 01 | 30600105 | 2a2 | 100 | 50.9 | 15.0% | 43.3 | 7.63 | 0.1394 | 0.12 | 0.02 | NATURAL GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | NATURAL GAS-FIRED | |
89 | 85 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0044 | BOILER HOUSE 2: BOILER #11 - BLAST FURNACE DEPT | 04 | 10200601 | 1a1 | 225 | 25.7 | 69.2% | 7.9 | 17.78 | 0.0654 | 0.02 | 0.05 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
90 | 86 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0044 | BOILER HOUSE 2: BOILER #11 - BLAST FURNACE DEPT | 01 | 10200704 | 1a1 | 225 | 31.7 | 69.2% | 9.8 | 21.96 | 0.0454 | 0.01 | 0.03 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | BLAST FURNACE GAS | |
91 | 87 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0048 | BOILER HOUSE 2: BOILER #12 - BLAST FURNACE DEPT | 04 | 10200601 | 1a1 | 225 | 24.8 | 69.2% | 7.6 | 17.15 | 0.0456 | 0.01 | 0.03 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
92 | 88 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0048 | BOILER HOUSE 2: BOILER #12 - BLAST FURNACE DEPT | 01 | 10200704 | 1a1 | 225 | 21.2 | 69.2% | 6.5 | 14.70 | 0.0436 | 0.01 | 0.03 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | BLAST FURNACE GAS | |
93 | 89 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0048 | BOILER HOUSE 2: BOILER #12 - BLAST FURNACE DEPT | 02 | 10200707 | 1a1 | 225 | 64.5 | 69.2% | 19.9 | 44.67 | 0.138 | 0.04 | 0.10 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | COKE OVEN GAS | |
94 | 90 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0041 | BOILER HOUSE 1: BOILERS 1 TO 7 | 01 | 10200704 | 1a2 | 60 | 66.0 | 15.0% | 56.1 | 9.89 | 0.1502 | 0.13 | 0.02 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | BLAST FURNACE GAS | |
95 | 91 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0041 | BOILER HOUSE 1: BOILERS 1 TO 7 | 04 | 10200601 | 1a2 | 420 | 44.6 | 15.0% | 37.9 | 6.69 | 0.1538 | 0.13 | 0.02 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
96 | 92 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0041 | BOILER HOUSE 1: BOILERS 1 TO 7 | 02 | 10200707 | 1a2 | 559 | 134.2 | 15.0% | 114.0 | 20.12 | 0.4103 | 0.35 | 0.06 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | COKE OVEN GAS | |
97 | 93 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0042 | BOILER HOUSE 1: BOILERS 8 TO 10 | 04 | 10200602 | 1a2 | 60 | 19.1 | 15.0% | 16.3 | 2.87 | 0.0659 | 0.06 | 0.01 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
98 | 94 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0042 | BOILER HOUSE 1: BOILERS 8 TO 10 | 01 | 10200704 | 1a2 | 80 | 28.3 | 15.0% | 24.0 | 4.24 | 0.0644 | 0.05 | 0.01 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | BLAST FURNACE GAS | |
99 | 95 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0042 | BOILER HOUSE 1: BOILERS 8 TO 10 | 02 | 10200707 | 1a2 | 60 | 57.5 | 15.0% | 48.9 | 8.63 | 0.1758 | 0.15 | 0.03 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | COKE OVEN GAS | |
100 | 96 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0015 | SLAB FURNACE #1 | 02 | 39000689 | 7a | 321.8 | 84.9 | 77.0% | 19.5 | 65.40 | 0.4144 | 0.10 | 0.32 | PROCESS GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL |
101 | 97 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0015 | SLAB FURNACE #1 | 01 | 39000689 | 7a | 321.8 | 266.2 | 77.0% | 61.2 | 205.00 | 0.7086 | 0.16 | 0.55 | NATURAL GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
102 | 98 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0018 | SLAB FURNACE #4 | 01 | 39000689 | 7a | 495 | 113.8 | 77.0% | 26.2 | 87.65 | 0.9587 | 0.22 | 0.74 | NATURAL GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
103 | 99 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0122 | SLAB FURNACE #2 | 02 | 39000689 | 7a | 322 | 82.2 | 77.0% | 18.9 | 63.32 | 0.3938 | 0.09 | 0.30 | PROCESS GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
104 | 100 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0122 | SLAB FURNACE #2 | 01 | 39000689 | 7a | 322 | 149.2 | 77.0% | 34.3 | 114.89 | 0.6908 | 0.16 | 0.53 | NATURAL GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
105 | 101 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0123 | SLAB FURNACE #3 | 02 | 39000689 | 7a | 322 | 101.6 | 77.0% | 23.4 | 78.19 | 0.4321 | 0.10 | 0.33 | PROCESS GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
106 | 102 | 119813AAI | 7044.1 | US Steel Granite City | 3312 | 0123 | SLAB FURNACE #3 | 01 | 39000689 | 7a | 322 | 162.8 | 77.0% | 37.5 | 125.39 | 0.7052 | 0.16 | 0.54 | NATURAL GAS | IN-PROCESS FUEL USE | NATURAL GAS | GENERAL | |
107 | 103 | 157851AAA | 4875.6 | Dynegy Midwest Generation Inc | 4911 | 0001 | *BOILER #1 | 01 | 10100202 | 8a | 5890 | 1106.9 | -20.0% | 1328.3 | -221.39 | 3.627 | 4.35 | -0.73 | COAL - SUBBITUMINOUS | ||||
108 | 104 | 157851AAA | 4875.6 | Dynegy Midwest Generation Inc | 4911 | 0002 | *'BOILER #2 | 01 | 10100202 | 8a | 5900 | 1495.3 | -22.2% | 1827.6 | -332.29 | 3.547 | 4.34 | -0.79 | COAL - SUBBITUMINOUS | ||||
109 | 105 | 157851AAA | 4875.6 | Dynegy Midwest Generation Inc | 4911 | 0013 | *BOILER #3 | 01 | 10100202 | 8a | 5800 | 2271.6 | 7.8% | 2095.0 | 176.68 | 6.624 | 6.11 | 0.52 | COAL - SUBBITUMINOUS | ||||
110 | 106 | 163045ADT | 168.3 | Elementis Pigments Inc | 2816 | 0061 | Erie City boiler | 01 | 10200601 | 1a1 | 135 | 41.4 | 69.2% | 12.7 | 28.65 | 0.258 | 0.08 | 0.18 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
111 | 107 | 163121AAY | 250.1 | Environmental Management Corp | 4961 | 0001 | BOILERS #1, #2 AND #3 | 01 | 10200601 | 1a1 | 393 | 22.4 | 69.2% | 6.9 | 15.53 | 0.0553 | 0.02 | 0.04 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
112 | 108 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0037 | 430B-1: Auxiliary boiler | 01 | 10200701 | 1a1 | 396 | 120.5 | 69.2% | 37.1 | 83.42 | 0.3296 | 0.10 | 0.23 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | > 100 MBTU/HR | |
113 | 109 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0235 | 431B-20: North Plant Boiler | 01 | 10200501 | 1b1 | 249 | 22.3 | 52.4% | 10.6 | 11.69 | 0.0398 | 0.02 | 0.02 | DISTILLATE OIL #2 | EXTERNAL COMBUSTION BOILERS | DISTILLATE OIL | GRADES 1 AND 2 OIL | |
114 | 110 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0003 | 111B-1A: Atmospheric heater | 01 | 30600104 | 2a1 | 376.5 | 46.4 | 28.6% | 33.1 | 13.25 | 0.1345 | 0.10 | 0.04 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
115 | 111 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0004 | 111B-1B: Atmospheric heater | 01 | 30600104 | 2a1 | 376.5 | 47.2 | 28.6% | 33.7 | 13.47 | 0.1362 | 0.10 | 0.04 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
116 | 112 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0005 | 111B-2: Crude vacuum heater | 01 | 30600104 | 2a1 | 219.8 | 18.1 | 28.6% | 12.9 | 5.17 | 0.057 | 0.04 | 0.02 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
117 | 113 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0050 | 109B-62: Steam HC reformer heater | 01 | 30600104 | 2a1 | 113.3 | 55.2 | 28.6% | 39.5 | 15.78 | 0.1751 | 0.13 | 0.05 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
118 | 114 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0070 | 123B-2: Feed preheater | 01 | 30600106 | 2a1 | 121.2 | 54.5 | 28.6% | 38.9 | 15.56 | 0.1428 | 0.10 | 0.04 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
119 | 115 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0011 | 113B-1: Coker 1 charge heater | 01 | 30600104 | 2a2 | 88.8 | 16.0 | 15.0% | 13.6 | 2.40 | 0.0439 | 0.04 | 0.01 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
120 | 116 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0012 | 113B-3: Coker 1 charge heater | 01 | 30600104 | 2a2 | 88.8 | 26.7 | 15.0% | 22.7 | 4.00 | 0.0721 | 0.06 | 0.01 | OTHER GASEOUS FUEL | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
121 | 117 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0019 | 116B-1: Charge heater and stabilizer reboiler | 01 | 30600104 | 2a2 | 89.9 | 41.5 | 15.0% | 35.3 | 6.23 | 0.1198 | 0.10 | 0.02 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
122 | 118 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0021 | 118B-1: Hot oil heater | 01 | 30600104 | 2a2 | 93.8 | 15.6 | 15.0% | 13.3 | 2.35 | 0.044 | 0.04 | 0.01 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
123 | 119 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0048 | 108B-41: Process heater | 01 | 30600104 | 2a2 | 44 | 22.7 | 15.0% | 19.3 | 3.41 | 0.0614 | 0.05 | 0.01 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
124 | 120 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0064 | 113B-2: Coker 1 charge heater | 01 | 30600106 | 2a2 | 88.8 | 16.4 | 15.0% | 13.9 | 2.46 | 0.045 | 0.04 | 0.01 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
125 | 121 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0066 | 116B-2: Interheater and naphtha stripper reboiler | 01 | 30600106 | 2a2 | 84.2 | 24.9 | 15.0% | 21.1 | 3.73 | 0.0818 | 0.07 | 0.01 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
126 | 122 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0073 | 123B-5: Reheat furnace | 01 | 30600106 | 2a2 | 42 | 17.5 | 15.0% | 14.9 | 2.63 | 0.0472 | 0.04 | 0.01 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
127 | 123 | 197090AAI | 2877.3 | CITGO Petroleum Corp | 2911 | 0074 | 125B-1 and 125B-2: Feed heater and stripper reboil | 01 | 30600106 | 2a2 | 100 | 32.0 | 15.0% | 27.2 | 4.80 | 0.0863 | 0.07 | 0.01 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
128 | 124 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0002 | AUX BOILER | 03 | 30600104 | 1a1 | 600 | 35.6 | 69.2% | 11.0 | 24.65 | 0.1013 | 0.03 | 0.07 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | > 100 MBTU/HR | |
129 | 125 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0018 | Crude unit heaters (#1B1A and #1B1B) | 01 | 30600104 | 2a1 | 778 | 288.5 | 28.6% | 206.0 | 82.42 | 0.7786 | 0.56 | 0.22 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
130 | 126 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0019 | Crude unit vacuum heater | 01 | 30600106 | 2a1 | 277 | 117.5 | 28.6% | 83.9 | 33.58 | 0.3157 | 0.23 | 0.09 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
131 | 127 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0021 | Coker charge heaters (East and West) | 01 | 10200701 | 2a1 | 732 | 123.3 | 28.6% | 88.1 | 35.23 | 0.3185 | 0.23 | 0.09 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
132 | 128 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0025 | Reformer charge heaters (2B3, 2B4, 2B5, 2B6) | 01 | 30600106 | 2a1 | 680 | 97.6 | 28.6% | 69.7 | 27.89 | 0.2593 | 0.19 | 0.07 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
133 | 129 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0028 | Pretreat debut reboil 17-B-2 | 01 | 10200701 | 2a1 | 164 | 15.8 | 28.6% | 11.3 | 4.50 | 0.0454 | 0.03 | 0.01 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
134 | 130 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0033 | CHD react charge heater 3B1 | 01 | 30600104 | 2a1 | 158 | 41.4 | 28.6% | 29.6 | 11.83 | 0.1163 | 0.08 | 0.03 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | GAS FIRED | |
135 | 131 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0034 | CHD strip reboiler 3B2 | 01 | 10200701 | 2a1 | 129 | 42.6 | 28.6% | 30.4 | 12.16 | 0.1063 | 0.08 | 0.03 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
136 | 132 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0038 | Alky isostrip reboiler heater 7B1 | 01 | 10200701 | 2a1 | 171 | 34.1 | 28.6% | 24.3 | 9.73 | 0.1065 | 0.08 | 0.03 | PROCESS GAS | EXTERNAL COMBUSTION BOILERS | PROCESS GAS | PETROLEUM REFINERY GAS | |
137 | 133 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0113 | Crude unit feed preheater 1-B3/13-B-4 | 01 | 30600106 | 2a1 | 240 | 30.7 | 28.6% | 21.9 | 8.77 | 0.0846 | 0.06 | 0.02 | PROCESS GAS | PETROLEUM INDUSTRY | PROCESS HEATERS | PROCESS GAS-FIRED | |
138 | 134 | 197800AAA | 7896.2 | Exxon Mobil Oil Corp | 2911 | 0038 | Alky isostrip reboiler heater 7B1 | 02 | 30600103 | 2b1 | 171 | 23.3 | 76.2% | 5.5 | 17.74 | 0.0696 | 0.02 | 0.05 | RESIDUAL OIL #4 | PETROLEUM INDUSTRY | PROCESS HEATERS | OIL FIRED | |
139 | 135 | 197800AAD | 198.2 | Loders Croklaan USA | 2079 | 0043 | JOHNSTON BOILER | 01 | 10200602 | 1a2 | 93.7 | 41.5 | 15.0% | 35.3 | 6.23 | 0.114 | 0.10 | 0.02 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | 10-100 MMBTU/HR | |
140 | 136 | 197800ABZ | 1056.4 | Flint Hills Resources LP | 2865 | 0021 | 2 BOILERS (CB-703, CB-704) | 01 | 10200601 | 1a1 | 450 | 55.2 | 69.2% | 17.0 | 38.24 | 0.1628 | 0.05 | 0.11 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
141 | 137 | 197800ABZ | 1056.4 | Flint Hills Resources LP | 2865 | 0119 | BOILER CB-706 | 01 | 10200601 | 1a1 | 370.2 | 17.8 | 69.2% | 5.5 | 12.30 | 0.0254 | 0.01 | 0.02 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
142 | 138 | 197809AAC | 227.0 | Caterpillar Inc | 3531 | 0004 | Boiler #2 | 01 | 10200601 | 1a1 | 112.6 | 16.1 | 69.2% | 5.0 | 11.15 | 0.0837 | 0.03 | 0.06 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
143 | 139 | 197809AAC | 227.0 | Caterpillar Inc | 3531 | 0005 | Boiler #3 | 01 | 10200601 | 1a1 | 175 | 40.0 | 69.2% | 12.3 | 27.66 | 0.079 | 0.02 | 0.05 | NATURAL GAS | EXTERNAL COMBUSTION BOILERS | NATURAL GAS | > 100 MBTU/HR | |
144 | 140 | 197809AAO | 60970.8 | Midwest Generation LLC | 4911 | 0009 | Joliet 9: Unit 6 cyclone boiler | 01 | 10100203 | 8a | 2886 | 5418.6 | 81.9% | 981.2 | 4437.33 | 16.9076 | 3.06 | 13.85 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | CYCLONE FURNACE | |
145 | 141 | 197809AAO | 60970.8 | Midwest Generation LLC | 4911 | 0031 | Joliet 29: Unit 7 Boilers 71 and 72 | 01 | 10100202 | 8a | 4558 | 1760.7 | 25.0% | 1320.5 | 440.16 | 6.0416 | 4.53 | 1.51 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
146 | 142 | 197809AAO | 60970.8 | Midwest Generation LLC | 4911 | 0033 | Joliet 29: Unit 8 Boilers 81 and 82 | 01 | 10100202 | 8a | 3193 | 1879.2 | 26.2% | 1386.3 | 492.89 | 5.9909 | 4.42 | 1.57 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | BITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
147 | 143 | 197810AAK | 18014.4 | Will County Electric Generating Station | 4911 | 0010 | UNIT #1 BOILER CYCLONE | 02 | 10100223 | 8a | 1728 | 2679.0 | 85.1% | 397.9 | 2281.09 | 9.5894 | 1.42 | 8.17 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | CYCLONE FURNACE | |
148 | 144 | 197810AAK | 18014.4 | Will County Electric Generating Station | 4911 | 0012 | UNIT #2 BOILER CYCLONE | 02 | 10100223 | 8a | 1712 | 2531.0 | 83.1% | 426.6 | 2104.41 | 9.1506 | 1.54 | 7.61 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | CYCLONE FURNACE | |
149 | 145 | 197810AAK | 18014.4 | Will County Electric Generating Station | 4911 | 0014 | UNIT #3 BOILER PULV. DRY BOTTOM - TANGENTIALY FIRE | 02 | 10100222 | 8a | 2709 | 873.1 | 23.1% | 671.6 | 201.48 | 2.7744 | 2.13 | 0.64 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
150 | 146 | 197810AAK | 18014.4 | Will County Electric Generating Station | 4911 | 0016 | UNIT #4 BOILER PULV. DRY BOTTOM - TANGENTIALY FIRE | 02 | 10100222 | 8a | 5016 | 1690.8 | 35.7% | 1086.9 | 603.86 | 6.0994 | 3.92 | 2.18 | COAL - SUBBITUMINOUS | EXTERNAL COMBUSTION BOILERS | SUBBITUMINOUS COAL | PULVERIZED COAL: DRY BOTTOM | |
151 | All Sources in Chicago and Metro-East NAAs, Total | 90419 | 44625 | 46.3% | 23959 | 20666 | 143 | 74 | 69 |
A | B | C | D | E | F | G | H | I | J | K | L | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Table I-1: NOx Reductions from the Application of NOx RACT (Reductions by Categories) | ||||||||||||
2 | Mydocument/TSD/NOx RACT-Attachments.xls | ||||||||||||
3 | |||||||||||||
4 | Emission Category Description | Category Designation | No. of Entries | No. of Units | Heat Input mmbtu/hr | 2005 NOx Emissions tpy | Estimated NOx RACT Reduction , % | Estimated Controlled NOx tpy | Estimated Nox Reduction Tons | Unit Typical Ozone Season NOx tons/day | Estimated Ozone Season Controlled NOx, TPD | Estimated Ozone season NOx Reduction, TPD | |
5 | Chicago NAA | ||||||||||||
6 | Gaseous Fuel-fired Boilers >100 mmBtu/hr, Total | 1a1 | 22 | 34 | 6911.9 | 1196.5 | 69.2% | 368.2 | 828.3 | 2.79 | 0.86 | 1.93 | |
7 | Gaseous fuel-fired Boilers < =100 mmBtu/hr, Total | 1a2 | 6 | 20 | 1273.9 | 156.6 | 15.0% | 133.1 | 23.5 | 0.63 | 0.54 | 0.09 | |
8 | Dist. oil Boilers >100 mmBtu/hr, Total | 1b1 | 1 | 1 | 249 | 22.3 | 52.4% | 10.6 | 11.7 | 0.040 | 0.02 | 0.02 | |
9 | Solid Fuel Boilers >250 mmbtu/hr, Total | 1e2 | 3 | 3 | 997.5 | 2330.2 | 73.9% | 607.9 | 1722.3 | 8.93 | 2.33 | 6.60 | |
10 | Solid Fuel <=250, >100 mmbtu/hr, Total | 1e3 | 1 | 1 | 212 | 21.6 | 63.8% | 7.8 | 13.8 | 0.00 | 0.00 | 0.00 | |
11 | Solid Fuel Boilers <=100 mmbtu/hr, Total | 1e4 | 5 | 5 | 376.2 | 476.7 | 15.0% | 405.2 | 71.5 | 1.61 | 1.37 | 0.24 | |
12 | Process Htrs Gas fired >100 mmBtu/hr, Total | 2a1 | 16 | 41 | 6672.6 | 1526.0 | 28.6% | 1090.0 | 436.0 | 4.19 | 2.99 | 1.20 | |
13 | Process Htrs Gas-fired< =100 mmBtu/hr, Total | 2a2 | 9 | 10 | 720.3 | 213.3 | 15.0% | 181.3 | 32.0 | 0.60 | 0.51 | 0.09 | |
14 | Process Htrs, Residual Oil-fired, >100 mmBtu/hr, Total | 2b1 | 1 | 1 | 171 | 23.3 | 76.2% | 5.5 | 17.7 | 0.07 | 0.02 | 0.05 | |
15 | Process Htrs, Other Oil-fired, <100 mmBtu/hr, Total | 2c3 | 1 | 1 | 17 | 26.5 | 15.0% | 22.5 | 4.0 | 0.10 | 0.09 | 0.02 | |
16 | Glass melting Furnaces, Total | 3 | 1 | 4 | 45 | 731.9 | 50.0% | 366.0 | 366.0 | 2.02 | 1.01 | 1.01 | |
17 | Lime Kilns, Total | 5a | 2 | 2 | 588.9 | 734.4 | 30.0% | 514.1 | 220.3 | 2.54 | 1.78 | 0.76 | |
18 | Annealing Furnace, Iron and Steel, Total | 7b | 1 | 1 | 123 | 44.1 | 60.0% | 17.6 | 26.5 | 0.15 | 0.06 | 0.09 | |
19 | EGU Coal-fired Boilers, Total | 8a | 13 | 15 | 37802 | 24827.2 | 57.3% | 10612.9 | 14214.3 | 82.22 | 34.59 | 47.63 | |
20 | All Sources in Chicago NAA, Total | 82 | 139 | 56160.30 | 32331 | 56% | 14343 | 17988 | 105.9 | 46.2 | 59.7 | ||
21 | Metro-East NAA | ||||||||||||
22 | Gaseous Fuel-fired Boilers >100 mmBtu/hr, Total | 1a1 | 10 | 6 | 3460 | 730.1 | 69.2% | 224.6 | 505.4 | 2.02 | 0.62 | 1.40 | |
23 | Gaseous Fuel-fired Boilers <=100 mmBtu/hr, Total | 1a2 | 7 | 10 | 1305 | 364.9 | 15.0% | 310.2 | 54.7 | 1.06 | 0.90 | 0.16 | |
24 | Process Htrs Gas fired >100 mmBtu/hr, Total | 2a1 | 16 | 16 | 2776.7 | 2184.4 | 28.6% | 1560.3 | 624.1 | 6.58 | 4.70 | 1.88 | |
25 | Process Htrs Gas fired <100 mmBtu/hr, Total | 2a2 | 15 | 15 | 1395.3 | 765.2 | 15.0% | 650.4 | 114.8 | 2.10 | 1.78 | 0.31 | |
26 | Reheat Furnaces, Iron and Steel, Total | 7a | 8 | 5 | 2681.6 | 1008.5 | 77.0% | 231.9 | 776.5 | 4.62 | 1.06 | 3.56 | |
27 | EGU Coal-fired Boilers, Total | 8a | 5 | 5 | 22540 | 7241 | 8.3% | 6639 | 602 | 20.6 | 18.8 | 1.8 | |
28 | All Sources in Metro-East NAA, Total | 61 | 57 | 34158.60 | 12294 | 21.8% | 9617 | 2678 | 37.0 | 27.9 | 9.1 | ||
29 | Chicago and Metro-East NAA (Combined) | ||||||||||||
30 | Gaseous Fuel-fired Boilers >100 mmBtu/hr, Total | 1a1 | 32 | 40 | 10371.9 | 1926.5 | 69% | 592.8 | 1333.8 | 4.8 | 1.5 | 3.3 | |
31 | Gaseous fuel-fired Boilers < =100 mmBtu/hr, Total | 1a2 | 13 | 30 | 2578.9 | 521.5 | 15% | 443.3 | 78.2 | 1.7 | 1.4 | 0.3 | |
32 | Dist. oil Boilers >100 mmBtu/hr, Total | 1b1 | 1 | 1 | 249 | 22.3 | 52.4% | 10.6 | 11.7 | 0.040 | 0.02 | 0.02 | |
33 | Solid Fuel Boilers >250 mmbtu/hr, Total | 1e2 | 3 | 3 | 997.5 | 2330.2 | 73.9% | 607.9 | 1722.3 | 8.93 | 2.33 | 6.60 | |
34 | Solid Fuel <=250, >100 mmbtu/hr, Total | 1e3 | 1 | 1 | 212 | 21.6 | 63.8% | 7.8 | 13.8 | 0.00 | 0.00 | 0.00 | |
35 | Solid Fuel Boilers <=100 mmbtu/hr, Total | 1e4 | 5 | 5 | 376.2 | 476.7 | 15.0% | 405.2 | 71.5 | 1.61 | 1.37 | 0.24 | |
36 | Process Htrs Gas fired >100 mmBtu/hr, Total | 2a1 | 32 | 57 | 9449.3 | 3710.4 | 0.6 | 2650.3 | 1060.1 | 10.8 | 7.7 | 3.1 | |
37 | Process Htrs Gas-fired< =100 mmBtu/hr, Total | 2a2 | 24 | 25 | 2115.6 | 978.5 | 0.3 | 831.7 | 146.8 | 2.7 | 2.3 | 0.4 | |
38 | Process Htrs, Residual Oil-fired, >100 mmBtu/hr, Total | 2b1 | 1 | 1 | 171 | 23.3 | 76.2% | 5.5 | 17.7 | 0.07 | 0.02 | 0.05 | |
39 | Process Htrs, Other Oil-fired, <100 mmBtu/hr, Total | 2c3 | 1 | 1 | 17 | 26.5 | 15.0% | 22.5 | 4.0 | 0.10 | 0.09 | 0.02 | |
40 | Glass melting Furnaces, Total | 3 | 1 | 4 | 45 | 731.9 | 50.0% | 366.0 | 366.0 | 2.02 | 1.01 | 1.01 | |
41 | Lime Kilns, Total | 5a | 2 | 2 | 588.9 | 734.4 | 30.0% | 514.1 | 220.3 | 2.54 | 1.78 | 0.76 | |
42 | Reheat Furnaces, Iron and Steel, Total | 7a | 8 | 5 | 2681.6 | 1008.5 | 77.0% | 231.9 | 776.5 | 4.62 | 1.06 | 3.56 | |
43 | Annealing Furnace, Iron and Steel, Total | 7b | 1 | 1 | 123 | 44.1 | 60.0% | 17.6 | 26.5 | 0.15 | 0.06 | 0.09 | |
44 | EGU Coal-fired Boilers, Total | 8a | 18 | 20 | 60342.00 | 32068.6 | 46.2% | 17252.1 | 14816.5 | 102.9 | 53.4 | 49.4 | |
45 | All Sources in Chicago and Metro-East NAA, Total | 143 | 196 | 90318.9 | 44625 | 46.31% | 23959 | 20666 | 142.9 | 74.1 | 68.9 | ||
46 | |||||||||||||
47 | Tabulation by Broad Categories | ||||||||||||
48 | Industrial Boilers | 45 | 4300.68 | 71.7% | 1219.12 | 3081.56 | |||||||
49 | Industrial Boilers | 35 | 998.2 | 15.0% | 848.4 | 149.7 | |||||||
50 | Process Heaters | 58 | 3733.7 | 28.9% | 2655.8 | 1077.9 |
51 | Process Heaters | 26 | 1004.95 | 15.0% | 854.21 | 150.74 | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
52 | Glass Melting Furnaces | 4 | 732 | 50% | 366 | 366 | |||||||
53 | Lime Kilns, Total | 2 | 734 | 30% | 514 | 220 | |||||||
54 | Iron and Steel, (reheat, annealing and galvanizing furnaces) | 2 | 1052.6 | 76.3% | 249.6 | 803.0 | |||||||
55 | EGU Coal-fired Boilers, Total | 20 | 32068.6 | 46.2% | 17252.1 | 14816.5 |