1. TITLE 35: ENVIRONMENTAL PROTECTION SUBTITLE E:
    2. AGRICULTURE RELATED WATER POLLUTION
    3. CHAPTER II: ENVIRONMENTAL PROTECTION AGENCY
    4. PART 570
    5. DESIGN AND MAINTENANCE CRITERIA REGARDING
    6. RUNOFF FIELD APPLICATIONS SYSTEMS
    7. SUBPART A: INTRODUCTION
    8. Section
    9. SUBPART B: DESIGN CRITERIA
    10. Section
    11. SUBPART A: INTRODUCTION
    12. Section 570.101 Purpose
    13. Section 570.102 Definitions
    14. SUBPART B: DESIGN CRITERIA
    15. Section 570.201 Runoff Field Application System General Design Criteria
    16. Section 570.205 Specifications for Vegetation Establishment
    17. Section 570.206 Operation and Maintenance Criteria
    18. Section 570.207 Innovative Designs
    19. Section 570.APPENDIX A
    20. Design Procedure Outlined
    21. Section 570.APPENDIX B
    22. Procedure to Estimate Volume of Freedlot Runoff*
    23. Section 570.APPENDIX C
    24. Procedure to Estimate Soil Infiltration Rate
    25. Section 570.APPENDIX D
    26. Procedure to Determine Slopes
    27. GRAPHIC MATERIALSee printed copy of IAC for detail
    28. GRAPHIC MATERIAL See printed copy of IAC for detail
    29. Figure D-1: Field set-up for determining slope
    30. 570.APPENDIX E
    31. Tables to Determine Dimensions of Field Application Areas
    32. Figure E1: How to Use Table E-1.
    33. GRAPHIC MATERIAL See printed copy of IAC for detail
    34. Table E-1 Runoff Field Application Areas (square feet).
    35. Section 570.APPENDIX F
    36. Recommended Effluent Transport Systems Designs
    37. Section 570.APPENDIX G
    38. Graph for Determining Flow Rate Over Field Application
    39. GRAPHIC MATERIAL See printed copy of IAC for detail
    40. Section 570.APPENDIX H
    41. Recommended Distribution Manifold Designs
    42. GRAPHIC MATERIAL See printed copy of IAC for detail
    43. Section 570.APPENDIX I
    44. Recommended Junction Box Designs
    45. GRAPHIC MATERIAL See printed copy of IAC for detail
    46. Section 570.APPENDIX J
    47. Diagram of Setting Basin Components
    48. GRAPHIC MATERIAL See printed copy of IAC for detail
    49. 570.APPENDIX K
    50. Sample Design Problem
    51. GRAPHIC MATERIAL See printed copy of IAC for detail
    52. Figure K-1: Sample Design Problem


TITLE 35: ENVIRONMENTAL PROTECTION SUBTITLE E:

 


AGRICULTURE RELATED WATER POLLUTION


CHAPTER II: ENVIRONMENTAL PROTECTION AGENCY

 


PART 570

 


DESIGN AND MAINTENANCE CRITERIA REGARDING


RUNOFF FIELD APPLICATIONS SYSTEMS

 


SUBPART A: INTRODUCTION

 


Section

570.101  Purpose

570.102  Definitions

 


SUBPART B: DESIGN CRITERIA

 


Section

570.201  Runoff Field Application System General Design Criteria

570.202  Conditions for System Utilization

570.203  Planning Considerations

570.204  Component Design Criteria

570.205  Specifications for Vegetation Establishment

570.206  Operation and Maintenance Criteria

570.207  Innovative Designs

 

APPENDIX A:  Design Procedure Outlined

 

APPENDIX B:  Procedure to Estimate Volume of Feedlot Runoff

 

APPENDIX C:  Procedure to Estimate Soil Infiltration Rate

 

APPENDIX D:  Procedure to Determine Slopes

 

APPENDIX E:  Tables to Determine Dimensions of Field Application Areas

 

APPENDIX F:  Recommended Effluent Transport Systems Designs

 

APPENDIX G:  Graph for Determining Flow Rate Over Field Application Area

 

APPENDIX H:  Recommended Distribution Manifold Designs and Junction Box Designs

 

APPENDIX I:  Diagram of Settling Basin Components

 

APPENDIX J:  Sample Design Problem

 

AUTHORITY: Implementing and authorized by Section 4(m) of the Environmental Protection Act (Ill. Rev. Stat., 1979, ch. 111 1/2, par 1004(m)), and authorized by Rule 105(a) of Chapter 5 (35 Ill. Adm. code 502.305).

 

SOURCE: Adopted at 6 Ill. Reg. 9951, effective August 3, 1982.

 


SUBPART A: INTRODUCTION

 


 
Section 570.101
Purpose
a) The intent of this document is to present design and maintenance criteria for runoff field application systems (commonly called vegetative filter systems). These relatively inexpensive systems can be effectively utilized to prevent feedlot runoff generated by small livestock management facilities from polluting streams, rivers, and other waters. Small livestock management operations typically do not have the economic resources necessary to control their feedlot runoff with expensive lagoon-type zero-discharge systems. The vast majority of livestock management operations in Illinois are relatively small and, therefore, these criteria add to currently available procedures of preventing water pollution from livestock management facilities.
 
b) Runoff field applications systems need attentive maintenance to function properly. Consistent failure on the part of the operator to maintain a runoff field application system in good operational condition could result in violations of the Act and Regulations. Improper maintenance may also result in the facility meeting the criteria set forth in Rule 203 of Chapter 5. Under Rule 203, the Agency may require any animal-feeding operation discharging pollutants through a man-made device to obtain a National Pollutant Discharge Elimination System (NPDES) permit on a case-by-case determination considering primarily the amount of wastes reaching navigable waters.
 


Section 570.102  Definitions

 

Except as hereinafter stated, and unless a different meaning of the term is clear from its context, the definitions of terms used in this document shall be the same as those used in the Environmental Protection Act and Illinois Pollution Control Board regulations, Chapter 3 - Water Pollution (Title 35, Subtitle C, Chapter 1) and Chapter 5 - Livestock Wastes:

    
“Distribution Manifold” means a device designed, constructed and maintained to provide uniform sheet flow of settling basin effluent across the width of a runoff field application area.
“Effluent Transport System (ETS)” means a non-perforated pipe or other device designed, constructed, and maintained to transport settling basin effluent to a junction box and distribution manifold.
“Field Application Area (FAA)” means a vegetated area designed, constructed, and maintained to remove sediment, organic matter, and other pollutants from livestock management facility runoff by settling, dilution, absorption, adsorption, infiltration, assimilation, and other processes.

“Junction Box” means a device designed, constructed, and maintained to dissipate the energy of the anticipated hydraulic jump from the effluent transport system discharge and to proportionally split the flow to the distribution manifold(s).

       
“Livestock Waste” means livestock excreta and associated feed losses; bedding; wash waters; sprinkling waters from livestock cooling; solids removed from settling basins, lagoons, or holding ponds; precipitation polluted by falling on or flowing onto an animal feeding operation; and other materials polluted by livestock.
“Runoff Field Application System” means those collective constructions or devices, except sewers, used to collect, pump, settle, store, and land apply feedlot runoff which include, but are not limited to, settling basin, effluent transport system, junction box, distribution manifold, and field application area.
“Settling Basin” means a basin designed, constructed, and maintained to remove settleable solids in feedlot runoff by gravity.
SI:  Soil Infilitration rate (inches per hour).
VR:  volume of feedlot runoff to be infiltrated by the field
application area (cubic feet).
QF:  Design flow rate (gallons per minute) over the field application area at 1/2 inch depth of flow for a 2 hour contact time.


 
SUBPART B: DESIGN CRITERIA


Section 570.201  Runoff Field Application System General Design Criteria

 

Designing an acceptable runoff field application system shall involve:

 

a)  Meeting the Conditions for System Utilization.

 

b)  Evaluating the Planning Considerations.

 

c)  Meeting the Component Design Criteria.

 

d)  Meeting the Specifications for Vegetation Establishment.

 

e) Providing the operator with Operation and Maintenance Criteria at least equivalent to those contained herein, however, with consideration given to the particular circumstances of each system.

 

Section 570.202  Conditions for System Utilization

 

Runoff field application systems shall not be constructed or operated at a livestock management facility unless the following conditions are satisfied:

 

a) The livestock management facility confines less than or equal to 300 animal units, as animal unit is defined in Chapter 5 Livestock Wastes Regulations.

 

b) No NPDES permit is required for the facility or is currently issued to the facility, based upon the criteria set forth in Rule 203 of Chapter 5. The Agency will make this determination for the operator.

 

c) Sufficient land area with characteristics capable of meeting the design and maintenance criteria for runoff field application systems, as determined in accordance with Section 570.204(e) and Appendix E, exists or can be provided by reasonable means.

 

d) The runoff field application system is maintained in good operational condition as provided in Section 570.206.

 

Section 570.203  Planning Considerations

 

The following shall be evaluated in planning a runoff field application system:

 

a) Slopes and soil material, vegetative species, and time of year for proper establishment of vegetation. Also consider the necessity for irrigation of the field application area, visual aspects, and other special needs.

 

b)  Location of settling basin.

 

c)  Adequate drainage to insure satisfactory performance.

 

d) Provisions for preventing or designing for continuous or daily discharge of liquid waste to the field application area (e.g., provide temporary storage tanks for milking parlor wastewaters or provide alternate field application areas).

 

e) Provisions to allow harvesting activities without causing design or vegetative damage.

 

f) Provisions for excluding roof water and unpolluted surface water from the settling basin and field application area.

 

g) The need to mechanically distribute the flow uniformly across the top of the field application area.

 

h) Runoff field application systems designed to be located on soils with infiltration rates outside the range of 1.0 to 6.0 inches per hour, or that are otherwise designed or maintained such that the criteria contained herein are not satisfied, shall be considered innovative designs subject to Section 570.207.

 

Section 570.204  Component Design Criteria

 

a)  Settling Basin

 

1) Basin volume shall be 4.5 cubic feet per 100 square feet of area contributing runoff plus an additional 10% volume safety factor.

 

    
2) Ramp slope shall not be steeper than 12:1 (H:V), with 15:1 being preferred.
3) Basin depth shall be 2 to 4 feet.
4) Settling basins located where groundwater tables rise to within 2 feet of the surface shall be provided with foundation drainage.
5) The settling basin riser pipe should be 18 to 24 inches in diameter with vertical slots 1 inch by 4 inches high spaced at 120o intervals around the pipe. There should be 6 slots per foot of height with the bottom row of slots even with the settling basin floor. To avoid excess clogging, offset or locate the riser pipe as far as practicable from the inlet of the settling basin and attach 3/4 inch mesh expanded metal screen cover over the top of the riser pipe. Provide a ¾ inch mesh expanded metal screen ahead of the riser pipe so that all runoff entering the riser pipe must first cross the screen. Refer to Appendix I for a diagram.
6) The settling basin ramp, floor, end-wall, and side-walls should be designed, constructed, and maintained to withstand normal operation practices involving power machinery.

 

b)  Effluent Transport System

 

  
1) Pressurized effluent transport systems shall be designed by normal engineering hydraulic considerations including but not limited to static head, friction losses, flow velocity, and pipe diameter.
2) Gravity flow effluent transport systems may be designed as pipes flowing full or as open channels. Design velocity shall be 2 feet per second or greater to prevent solids deposition. Minimum pipe capacity shall equal or exceed the design flow rate (QF) over the field application area. The design feedlot runoff volume (VR) shall be calculated by Appendix B. Design flow rate (QF) can be obtained from Appendix G.
3) Closed pipes used for effluent transport systems shall be provided with some means of cleaning by rodding or flushing.

 

c)  Junction Box

 

   
1) A junction box shall be provided at the intersection of the effluent transport system and distribution manifold to dissipate the energy of the anticipated hydraulic jump from the effluent transport system discharge and to proportionally split the flow to the distribution manifold(s).
2) The recommended junction box design specifications are provided in Appendix H.
3) The junction box should be provided with a removable cover to allow entry for maintenance and prevent entry of objects that would interfere with the operation of the runoff field application system.
d) Distribution Manifold
   
1) Pressurized distribution manifolds shall be designed by normal engineering considerations including but not limited to static head, friction losses, flow velocity, and pipe diameter.
2) Gravity flow distribution manifolds shall be less than 50 feet long each and at least 2 feet shorter than the width of the field application area.
3) The following must be considered in the distribution manifold design:

 

A)  Construction material

B)  Length

C)  Capacity

D)  Slope (level)

E)  Solids removal and cleaning

F)  Providing uniform sheet flow

 

i)  Effluent transport system connection point

ii)  Capped ends

iii)  Orifice or V-notch weir design and spacing

iv)  Splash apron such as pea gravel or concrete

 

G)  Location of junction box

 

4) Recommended designs of distribution manifolds are provided in Appendix H.

 

5)  Distribution manifolds must be anchored securely while in operation.

 

e)  Runoff Field Application Area

 

    
1) The runoff field application area shall be located on gently sloping soils of moderate permeability supporting a heavy stand of grass vegetation and designed to operate by overland flow.
2) Slopes shall be shaped to cause applied runoff to flow uniformly across the design width for the entire length of the field application area.
3) The uniform sheet flow shall move downslope through the field application area flow length at a velocity that will provide a minimum contact time of two hours. Appendix E, gives minimum flow lengths needed to provide a contact time of 2 hours at various slopes.
4) Field application areas shall have a minimum width of 20 feet and a maximum width of 100 feet.
5) The range of soil infiltration rates specified in the planning considerations (1.0 to 6.0 inches per hour) insures that the infiltration capacity of the field application area will equal or exceed the volume of feedlot runoff to be infiltrated for the 1 year - 2 hour design rainstorm event. The following equation shall be used for designing the field application area (FAA):

 

FAA = VR x 12

(2 hours x S1) - 1.69

 

when: 1.0 < SI < 6.0 inches per hour

FAA in square feet.

VR in cubic feet.

 

6) The procedures for determining VR and SI are provided in Appendix B and C, respectively.

 


Section 570.205  Specifications for Vegetation Establishment

 

The following specifications shall apply to all runoff field application systems:

 

a) All trees, stumps, brush, rocks, and similar materials that can interfere with installing the field application area shall be removed. The materials shall be disposed of in a manner that is consistent with standards for maintaining and improving the quality of the environment and with proper functioning of the field application area.

 

b) The field application area shall be shaped to the grade and dimensions shown in the plan or as staked in the field. If necessary, topsoil shall be stockpiled and spread to the required grade and thickness. Excess spoil shall be disposed of in areas where it does not interfere with the required flow characteristics of the field application area.

 

c)  All areas disturbed during construction shall be vegetated.

 

d) To aid in the establishment of vegetation, feedlot runoff shall be prevented from entering the field application area through the use of temporary diversions until vegetation is established to a minimum height of 4 inches and 90 percent ground cover.

 

e) Immediately prior to seedbed preparation, apply the following minimum amounts of starter fertilizer per acre:

 

Nitrogen (N)-120 pounds of actual nitrogen

Phosphorus (P)-120 pounds of P2O5

Potassium (K) - 120 pounds K2O

 

f)  Apply limestone, if necessary, for the species to be grown.

 

g) Incorporate the required lime and fertilizer and prepare a firm seedbed to a depth of 3 inches. The seedbed shall be free from clods, stones, or other debris that might hamper proper seeding.

 

h) Select one of the following mixtures and seed according to the rate shown:

 

1)  Reed canarygrass - 25 lbs./acre

 

2) Mixture reed canarygrass and tall fescue - 15 lbs./acre of each species.

 

3) Use of species other than canarygrass or tall fescue shall be considered an innovative design.

 

i) Apply seed uniformly at a depth of 1/4 to 1/2 inch with a drill (band seed) or cultipacker type seeder or broadcast seed uniformly and cover to a depth of 1/4 to 1/2 inch with a cultipacker or harrow. If a drill or cultipacker seeder is used, seed across the slope or cut channel.

 

j)  Seeding dates shall be either:

 

1)  Early spring to May 15.

 

2) May 15 to August 1, provided sufficient water is provided for germination and vigorous growth.

 

3)  August 1 to September 10.

 

k) Mulch with clean straw using 2 tons of mulch per acre. The mulch must be uniformly spread over the seeded area.

 

l)  Anchor the mulch by one of the following methods:

 

1) Press it into the soil to a 2 inch depth by using a serrated straight disk or a dull farm disk set straight. Cross the slope perpendicular to the direction of the flow of water, or

 

 
2) Apply a netting on top of the mulch and anchor it with staples.

 


Section 570.206  Operation and Maintenance Criteria

 

The following operation and maintenance criteria shall apply as best management practices to all runoff field application systems:

 

a) Protect the field application area from damage by farm equipment, traffic and livestock. LIVESTOCK MUST BE FENCED OUT OF THE RUNOFF FIELD APPLICATION AREA.

 

b)  Avoid damaging the field application area with herbicides.

 

c) Fertilize the field application area when necessary to establish growth.

 

d) Harvest when the forage is at the proper state of maturity for maximum quality feed. No harvesting shall occur after September 15. Use the following guide for cutting stages and minimum cutting height for the species seeded:

 

1) Reed canarygrass - cut at early boot stage to heading minimum cutting height 6 inches.

 

2) Reed canarygrass - tall fescue mixture - cut at early boot to heading - minimum cutting height 6 inches.

 

e) Repair damage caused by erosion or equipment immediately so the runoff field application system will continue to perform properly. Rills and small channels must be repaired. A shallow furrow on the contour across the field application area can be used to reestablish sheet flow.

 

f) To prevent excess organic solids from entering the field application area:

 

1) Scrape feedlot regularly; however, do not scrape waste into settling facilities, but place in separate manure stacking area away from settling basin.

 

2) Drainage from manure stacking facilities should be directed to settling basin or contained.

 

3) Remove solids from the settling basin when 2 to 4 inches accumulate.

 

4) Scrape lot frequently during early spring. At least once each 7 days is recommended.

 

g) If organic wastes accumulate on the field application area and are damaging vegetation, redistribute wastes.

 

h) Remove solids that accumulate in the effluent transport system, junction box, and distribution manifold regularly.

 

i) Solids removed from runoff field application system components shall be disposed of pursuant to Technical Policy WPC-2-Design Criteria for Field Application of Livestock Waste.

 

j) Periodic soil testing of the field application area is suggested to determine changes in phosphorus, potassium, and pH levels.

 

 
    k) Each spring, relevel the distribution manifold and restore the design slope on other pipes.
    1. When vegetation of a kind other than reed canarygrass or tall fescue infests 20% or more of the field application area, the infested area shall be revegetated as provided in Section 570.205.

     


    Section 570.207  Innovative Designs

     

    It is strongly suggested that any operator contemplating use of runoff field application systems not designed, constructed or maintained in accordance with the design criteria contained herein receive PRIOR approval from the Agency for such system. The Agency will approve innovative designs should the operator present clear, cogent and convincing proof that the technique has a reasonable and substantial chance for meeting the requirements of the Act and Regulations, based upon conservative engineering principles. For further information contact the Division of Water Pollution Control - Permit Section in Springfield (217/782-0610), or the Agency regional office in your area.

     

    Examples of innovative designs are:

     

    a) Settling basin designed at less than 4.5 cubic feet per 100 square feet of drainage area.

     

    b)  Settling channel used instead of settling basin.

     

    c)  Use of terraces for field application area.

     

    d)  Riser pipe designed differently than provided herein.

     

    e)  Use of vegetation other than tall fescue or reed canarygrass.

     

    f)  Greater than 300 animal units on feedlot.

     

    g)  Distribution manifold designed for full pipe flow driven by gravity.

     

    h)  Not providing a junction box.

    i) Application of materials other than feedlot runoff, rainfall, or milking parlor washwaters to the runoff field application system (for example silage leachate, sewage, pesticides, oil, refuse).
    j) Use of field application area smaller than provided herein or with less than 2 hours contact time.
    k) Use of soils on runoff field application area with infiltration rates outside the range of 1.0 to 6.0 inches per hour.

    l)  Use of field application area widths greater than 100 feet.

     


    Section 570.APPENDIX A

     


    Design Procedure Outlined

     

    1.  Collect Site Specific Data

     

    a.  Types and Areas (sft) contributing drainage

    b.  Slope of Field Application Area (FAA) - Appendix D

     

    c.  Soil Infiltration Rate (SI) of FAA - Appendix C

     

    2.  Calculate Runoff Volume and Total Drainage Area

    Working Table in Appendix B

     

    3.  Settling Basin Design

     

    4.  Field Application Area Design

     

    FAA = (VR x 12)/[(2 x SI) - 1.69] (square feet)

     

    Dimensions from Appendix E

    5.  Calculate Flow onto Field Application Area

    Flows from Appendix G

    or

    Qf = (.0026) (FAA) (gpm)

    6.  Effluent Transport System Design

    Recommended Designs from Appendix F

    7.  Junction Box Design

    Recommended Design from Appendix H

    8.  Distribution Manifold Design

    Recommended Designs from Appendix H



    Section 570.APPENDIX B

     


    Procedure to Estimate Volume of Freedlot Runoff*

     

     

    (A) X

    (B) =

    (C)

     

    Type of

    Drainage Area

    Area

    (Square feet)

    Multiplication

    Factor (feet)

    Runoff Volume (Cubic feet)

           

    Roof

     

    0.1408

     
           

    Feedlot

         
    1. Paved or

    Concrete

     

    0.0991

     
           

    b. Earthen

     

    0.0748

     
           
    * Multiplication factor corresponds to Q of the U.S.D.A. - S.C.S. runoff equation.
    Storm event (I) is 1-year, 2-hour storm of 1.69 inches.
    Curve numbers (CN) are 100-roof; 95-paved; 91-earthen.
    S = (1000/CN) - 10
    Q = (I - 0.2S)/(I + 0.8S)

    1.  Feedlot Runoff Volume = Total of Column (C) (cubic feet).

     

    2.  Milking Parlor Washwater =

    gallons x.936 (cubic feet - per week)

    day

     

    3.  Design Runoff Volume (VR) = 1 + 2 (cubic feet).

    Use VR (cubic feet) for designing field application area.

    4. Total area (sum of column A in square feet) divided by 100 is used to design settling basin.
    5. To convert Runoff Volume (VR) from units of cubic feet into equivalent units of gallons, multiply cubic feet by 7.481 gallons/cubic feet.

     


    Section 570.APPENDIX C

     


    Procedure to Estimate Soil Infiltration Rate

     

    Soil infiltration rate for a runoff field application area can be determined by using:

     

    1. Any of three methods given in EPA Process Design Manual - Land Treatment of Municipal Wastewater dated October, 1981; Chapter 3.4 - Infiltration Rate Measurements.

     

    2.  The following modified cylinder infiltrometer method:

     

    Procedure

     

    A.  Preparing the test site

     

    Drive a rigid, leak-proof container approximately 6 inches into the ground taking care to avoid disturbing the soil as much as possible. This container should be approximately 2 feet long by at least 10 inches wide, and may be of any suitable material. A metal pipe is recommended (see FigureC-1).

     

    B.  Saturation and Swelling of the Soil

     

    Before conducting the test, saturate the soil for at least four hours, but preferably 8 hours, by refilling the container with clean water as needed.

     

    C.  Testing

     

    At the time of the test, adjust the water level to 12 inches above the soil surface. Allow the water level to drop six inches and then commence measuring the drop in water level at 15 minute intervals until the water has infiltrated. Repeat part C.

     

    D.  Recording Results

     

    Record results of all tests as the total minutes required for the last six inches of water to infiltrate (minutes/inch). Average the two tests at each site. For example:

     

    Site 1 - Data Recorded

     

    min

    inch

    min

    inch

    0

    6.0

    45

    2.5

    15

    4.5

    60

    2.0

    30

    3.5

    60

    2.0

     

     

     

    60 minutes= 60 = 15 min/inch

    (6 - 2 inches 4

     

    E.  Soil Infiltration Rate

     

    The soil infiltration rate (SI) is calculated at each site:

     

    SI = 36 = inch/hour =

    min/inch

    Example

     

    SI = 36 - 2.4 inch/hour

    15

     

    F. Average the soil infiltration rates from each testing site to calculate the SI value for the runoff field application area.

     

    These tests must not be made on frozen ground and include a safety factor in Part E to compensate for inherent inaccuracies in this procedure.

     

    3. Data from a modern U.S.D.A. - S.C.S. soil survey for the county where the runoff field application system will be installed. Use the Table of Engineering Properties - Physical and Chemical Properties for Permeability of the surface soil layer as follows:

     

    1. Locate the soil name and map symbol for the field application area on the map sheets (example - 386A, Downs).

     

    2. On the Physical and Chemical Properties Table locate the surface layer permeability rate.

     

    Example

     

    Table 15 -- Physical and Chemical Properties of Soils

     

    Soil and map symbol

    Depth (inches)

    Permeability (in/hr)

    386A, 386B

    0 - 7

    0.6 - 2.0

    Downs

    7 - 30

    0.6 - 2.0

     

    30 - 60

    0.6 - 2.0

     

    3. At the surface layer (0 - 7 inches for the example) use the average value of the permeability range to obtain SI.

     

    Example

     

    SI = 2.0 + 0.6 = 1.3 inches/hour

    2

     

    GRAPHIC MATERIAL See printed copy of IAC for detail Figure 1: Cylinder Infiltrometer

     


    Section 570.APPENDIX D

     


    Procedure to Determine Slopes

     

    Slope must be determined at the site of the runoff field application area to use Appendix E. Many methods are available to determine slope but all methods are based on the fact:

     


    GRAPHIC MATERIALSee printed copy of IAC for detail

     

    The following procedure can be used to determine slope.

     

    1. Obtain a 40 foot length of string or wire with a 25 foot section marked off (if you use nylon, measure the 25 feet with a steel tape because nylon stretches when pulled taut); carpenter's line level from a hardware store; a stake; a rod about 8 feet long (an 8 ft. 2 x 4 works well); a tape measure; a notebook and an assistant.

     

    2.  Set up your notes as follows:

     

    Site

    run (ft)

    rise (ft)

    1

    0

    0

    1-2

    25

     

    2-3

    25

     

    3-4

    25  

     

    etc.

     

    Refer to Figure D-1. 3.

     

      
    3. Stake one end of the string at point 1 and attach the other end to he rod so that there is 25 feet between the stake and rod, and he string can slide up and down the rod. With the string taut, evel the string in the center using the line level and record the rise at point 2 in your notes by measuring the string height at the rod.
    4. Repeat step 3 all the way down the field and calculate the slope by:

    Slope =A(100)(% or ft/100ft)

    B

     

    5.   the % slope for Appendix E.

     


    GRAPHIC MATERIAL See printed copy of IAC for detail

     


    Figure D-1: Field set-up for determining slope

     


    570.APPENDIX E


    Tables to Determine Dimensions of Field Application Areas

     


    Figure E1: How to Use Table E-1.

     


    GRAPHIC MATERIAL See printed copy of IAC for detail

     

    1.  Enter at slope of field application area from Appendix D.

    2.  Read down column and find corresponding length of field application area.

    3. Continue down column stopping at area closest to that previously calculated for your site.

    4.  Read left to find width of field application area.

     


    Table E-1 Runoff Field Application Areas (square feet).

     

    Slope (%)

    Length (ft)

    0.5

    300

    0.7

    375

    1.0

    425

    1.5

    525

    2.0

    600

    3.0

    750

    4.0

    800

                   

    20

    6,000

    7,500

    8,500

    10,500

    12,000

    15,000

    17,000

    25

    7,500

    9,375

    10,625

    13,125

    15,000

    18,750

    21,250

    30

    9,000

    11,250

    12,750

    15,750

    18,000

    22,500

    25,500

    35

    10,500

    13,125

    14,875

    18,375

    21,000

    26,250

    29,750

    40

    12,000

    15,000

    17,000

    21,000

    24,000

    30,000

    34,000

    45

    13,500

    16,875

    19,125

    23,625

    27,000

    33,750

    38,250

    50

    15,000

    18,750

    21,250

    26,350

    30,000

    37,500

    42,500

    55

    16,500

    20,625

    23,375

    28,875

    33,000

    41,250

    46,750

    60

    18,000

    22,500

    25,500

    31,500

    36,000

    45,000

    51,000

    65

    19,500

    24,375

    27,625

    24,125

    39,000

    48,750

    55,250

    70

    21,000

    26,250

    29,750

    36,750

    42,000

    52,500

    59,500

    75

    22,500

    28,125

    31,875

    39,375

    45,000

    56,250

    63,750

    80

    24,000

    30,000

    34,000

    42,000

    48,000

    60,000

    68,000

    85

    25,500

    31,875

    36,125

    44,625

    51,000

    63,750

    72,250

    90

    27,000

    33,750

    38,250

    47,250

    54,000

    67,500

    76,500

    95

    28,500

    35,625

    40,375

    49,875

    57,000

    71,250

    80,750

    100

    30,000

    37,500

    42,500

    52,500

    60,000

    75,000

    85,000

     


    Section 570.APPENDIX F


    Recommended Effluent Transport Systems Designs

     

     

    Type

    Mimimum Flow*

    of gpm)

    Minimum Slope (%)

    Design Velocity (fps)

    Matrials

    Dimensions

    Diagrams

               

    GRAPHIC MATERIAL See printed copy of IAC

    Pipe

    179

    0.5

    2

    PVC

    6” diam

     
     

    332

    0.4

    2

    PVC

    8” diam

     

    Open Channel

               
                 

    Rectangular

    224

    0.33

    2

    Concrete,

    Wood,

    Asphalt,

    Aluminum

    6” x 6”

     
                 

    Trapezoidal

    224

    0.37

    2

    Concrete,

    Wood,

    Asphalt,

    Aluminum

    b = 6”

    S = 2:1

    d = 3”  

     

     


    Section 570.APPENDIX G


    Graph for Determining Flow Rate Over Field Application

     


    GRAPHIC MATERIAL See printed copy of IAC for detail

     

     

     


    Section 570.APPENDIX H


    Recommended Distribution Manifold Designs


    GRAPHIC MATERIAL See printed copy of IAC for detail

     

     


    Section 570.APPENDIX I


    Recommended Junction Box Designs


    GRAPHIC MATERIAL See printed copy of IAC for detail

     

     


    Section 570.APPENDIX J


    Diagram of Setting Basin Components


    GRAPHIC MATERIAL See printed copy of IAC for detail

     

     


    570.APPENDIX K


    Sample Design Problem

     

    A livestock producer had 300 head of feeder cattle on a concrete feedlot (see Figure 1) and wanted to install a runoff field application system to control feedlot runoff which entered a nearby stream. The facility met the Conditions for System Utilization set forth in Section 570.202 and the runoff field application system was designed by following the procedure in Appendix A.

     

    1.  Site Specific Data

     

    A.  From Figure 1 and Appendix B:

     

    Concrete Feedlot Area  20,038 sft.

    (0.46 acres)

     
    Roof Area 4,792 sft.
       
      1. acres)
      All other drainage was diverted from the feedlot and field application area with gutters, curbs, and berms.
      B. From the procedure in Appendix D, the slope of the field application area was 1.0%.

       

      C. From the Soil Survey for the county the soil infiltration rate (SI) of the field application area was 2.0 inches/hour using the procedure in Appendix C (#3).

       

      2.  From Appendix B, runoff volume was calculated.

       

      Roof  4,785 sft. x 0.1408 = 673.7 cft.

       

      Feedlot 20,037 sft. x 0.0991 = 1985.7 cft.

       

      Design Runoff Volume (VR) = 2660 cft.

       

      From Appendix B, the total drainage area was calculated.

      20,037 + 4,785 = 24,822 square feet

       

      3  Settling Basin Design

       

      The total settling basin volume was calculated as provided in Section 570.204(a)(1).

       

      24,822 sft. x 4.5 cft.= 1117 cubic feet

      100 sft.

       

      1117 cft. x 10 = 112 cubic feet

       

      Total Volume = 1229 cubic feet

       

      From Appendix I, the settling basin dimensions were calculated after choosing 3 feet settling basin height (h), 12 feet width (b), and 15:1 slope.

       

      L1 = 3 x 15 = 45 feet

       

      V1 = (1/2) (12 x 3 x 45) = 810 cft.

       

      V2 = 1229 - 810 = 419 cft.

       

      L2 = 419/ (12 x 3) = 11 feet, 8 inches

       

      Round-off L2 to 12 feet.

       

      Foundation drainage title were not needed as the soil survey indicated the groundwater table did not rise above 5 ft. depth.

       

      A 24-inch diameter riser pipe was provided pursuant to Section 570.204 (5) and concrete was chosen as the settling basin construction material.

       

      4.  Field Application Area Design

       

      The field application area was calculated using Section 570.204(e)(4).

       

      FAA = 2660 x 12 = P31,920 = 13,818 sft.

      (2 x 2.0) - 1.69 minimum area needed

       

      Appendix E was used to determine the dimensions of the field application area using the next larger sized area of 14,875 sft.

       

      Slope    1.0%

      Length  425 feet

      Width    35 feet

      FAA    14,875 sft. (0.34 acres)

       

      5.  Cacluate Flow onto Field Application Area

       

      The flow onto the field application area was determined using Appendix G as being approximately 40 gpm.

       

      A more accurate calculation was made as follows:

       

      Qf = (0.0026) x FAA

       

      Qf = (0.0026) x 14,875 sft. = 38.7 gpm

       

      6.  Effluent Transport System Design

       

      A pipe was chosen to transport the settling basin effluent to the distribution manifold and was designed using Appendix F at the 179 gpm criteria (since this pipe design could handle 38.7 gpm).

       

      Slope     0.5 %

      PVC non-perforated pipe

      Diameter of pipe - 6 inches

       

      7.  Junction Box Design

       

      A junction box was constructed to the specifications provided in Appendix H.

       

      Adjustable slots were included in the drop boxes to compensate for frost heaving of the junction box in the future.

       

      8.  Distribution Manifold Design

       

      The distribution manifolds were designed using the 1/2 Pipe criteria at 150 gpm as provided in Appendix H.

       

      Length of each manifold = 35 feet - 2 feet= 16.5 ft.

      2

       

      An 8-inch diameter PVC pipe (17 feet long) was purchased and cut in half down the pipe length to provide 2 manifolds each 4-inches deep. Each manifold had 6 inches removed to provide the required length of 16.5 feet.

       

      Tin snips were used to cut V-notch weirs 12 inches apart on center on one side of each manifold with each notch cut 1.5 inches wide and 2.5 inches deep.

       

      The two distribution manifolds were placed in the previously installed junction box (the junction box was located in the center of the field application area width). Caps were provided over the outside end of each distribution manifold and 1/8 - inch wire staples were used to anchor each manifold at 5 foot spacings.

       

      A 1-foot wide pea gravel splash apron was provided below the V-notch weirs over the length of each manifold.

       


      GRAPHIC MATERIAL See printed copy of IAC for detail

       


      Figure K-1: Sample Design Problem

       